Evidence map›Paper›PMID 38356811›Full record

ArticlePakistan journal of medical sciences

Three-dimensional measurement and analysis of Mandibular Molar Distalization assisted by micro-implant anchorage combined with clear aligner.

Gengbing Lin, Mengwei Chen, Nan Guo, Xie Shi

Abstract read
In one paragraph

Article in Pakistan journal of medical sciences. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. [Advancements in biomechanics and orthodontic strategies for clear aligner therapy].Hua xi kou qiang yi xue za zhi = Huaxi kouqiang yixue zazhi = West China journal of stomatology · 2026
    Pooled it
  2. Review
  3. Article
  4. Review
  5. Article
  6. Therapeutic effect of Micro-Implant Anchorage in orthodontics.Pakistan journal of medical sciences · 2024
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Gengbing LinGengbing Lin, Department of Stomatology, Fujian Provincial People's Hospital, Affiliated People's Hospital of Fujian University of Traditional Chinese Medicine, Fuzhou 350004, Fujian, China.
Mengwei ChenMengwei Chen, Department of Orthodontics, Fujian Key Laboratory of Oral Diseases & Fujian Provincial Engineering Research Center of Oral Biomaterial & Stomatological Key lab of Fujian College and University, School and Hospital of Stomatology, Fujian Medical University & Institute of Stomatology, Fujian Medical University, Fuzhou 350004, Fujian, China.
Nan GuoNan Guo, Department of Stomatology, Fujian Provincial People's Hospital, Affiliated People's Hospital of Fujian University of Traditional Chinese Medicine, Fuzhou 350004, Fujian, China.
Xie ShiXie Shi, Department of Orthodontics, Fujian Key Laboratory of Oral Diseases & Fujian Provincial Engineering Research Center of Oral Biomaterial & Stomatological Key lab of Fujian College and University, School and Hospital of Stomatology, Fujian Medical University & Institute of Stomatology, Fujian Medical University, Fuzhou 350004, Fujian, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Objective: To investigate the effect of micro-implant anchorage combined with a clear aligner on the efficiency of mandibular molar distalization and the protection of anterior teeth anchorage, provide reference for clinical scheme design. Methods: This is a prospective study. Seventeen patients who were treated in the Orthodontics Department of the Hospital of Stomatology affiliated to Fujian Medical University from 2019 to 2021 and used Invisalign clear aligners to move mandibular molars distally were included and divided into two groups according to anchorage types: Group-A and Group-B. Group-A (ten cases) were treated without micro-implant anchorage, while Group-B (seven cases) were treated with micro-implant anchorage nails for enhanced anchorage. The effect of micro-implant anchorage on crown and root distal movement of mandibular molars and the difference in three-dimensional movement between mandibular molars and mandibular central incisors were analyzed. Results: The crown distalization efficiency of mandibular first and second molars in Group-B was 68.66% and 71.02%, respectively, which were higher than those in Group-A(p<0.05). The mandibular central incisors in Group-A showed labial displacement and a small amount of elongation, while those in Group-B showed less anchorage loss(p<0.05). In Group-A, the crown was tilted in the distal direction and moved in the buccal direction during mandibular molar distalization(p<0.05). While in Group-B, the crown was tilted in the distal directio (p<0.05) and the mandibular second molar was depressed(p<0.05). Conclusion: In the process of mandibular molar distalization assisted by micro-implant anchorage combined with a clear aligner, better protects the anchorage of the mandibular central incisor and improves the efficiency of the molar crown distalization.

Indexed as

Clear alignerMandibular molar distalizationMicro-implant anchorageThree-dimensional measurement

Identifiers

PMID38356811
PMCPMC10862430

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.