ArticleScientific reports2024
Assessment of deep learning segmentation for real-time free-breathing cardiac magnetic resonance imaging at rest and under exercise stress.
Article in Scientific reports, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
10 citing papers in PubMed, 10 citations in OpenAlex.
- CardioSynergyNet: A Closed-Loop Multi-Task Deep Learning Architecture for Cardiac Segmentation and Biomarkers with Diagnosis from Paired ED-ES Cine-MRI.Tomography (Ann Arbor, Mich.) · 2026Article
- Clinical evaluation of accelerated breath-held and free-breathing cine cardiac MRI using model-based deep learning reconstruction (SonicDL) in children and young adults.Pediatric radiology · 2026Article
- Comparative evaluation of artificial intelligence-deep learning-based cine short-axis segmentation and manual post-processing for left ventricular function and structure in cardiac magnetic resonance.Quantitative imaging in medicine and surgery · 2026Article
- A comparison of vendor artificial intelligence solutions for automated post-processing of short-axis cine images in cardiovascular magnetic resonance imaging.Scientific reports · 2026Article
- Deep Learning for Cardiac Wall Motion Analysis: A Review of Methods, Challenges, and Clinical Applications.Annals of biomedical engineering · 2026Review
- Deep Learning and Cardiovascular Diseases: An Updated Narrative Review.Journal of clinical medicine · 2026Review
- Pushing the limits of cardiac MRI: deep-learning based real-time cine imaging in free breathing vs breath hold.European radiology · 2026Article
- Intra- and inter-field strength reproducibility of deep-learning based real-time cardiac MRI cine sequences with breath hold and in free breathing.Scientific reports · 2025Article
- Simultaneous multi-slice cardiac real-time MRI at 0.55T.Magnetic resonance in medicine · 2025Article
- Towards a cardiovascular magnetic resonance foundation model for multi-task cardiac image analysis.Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors at 3 institutions in 2 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
In recent years, a variety of deep learning networks for cardiac MRI (CMR) segmentation have been developed and analyzed. However, nearly all of them are focused on cine CMR under breathold. In this work, accuracy of deep learning methods is assessed for volumetric analysis (via segmentation) of the left ventricle in real-time free-breathing CMR at rest and under exercise stress. Data from healthy volunteers (n = 15) for cine and real-time free-breathing CMR at rest and under exercise stress were analyzed retrospectively. Exercise stress was performed using an ergometer in the supine position. Segmentations of two deep learning methods, a commercially available technique (comDL) and an openly available network (nnU-Net), were compared to a reference model created via the manual correction of segmentations obtained with comDL. Segmentations of left ventricular endocardium (LV), left ventricular myocardium (MYO), and right ventricle (RV) are compared for both end-systolic and end-diastolic phases and analyzed with Dice's coefficient. The volumetric analysis includes the cardiac function parameters LV end-diastolic volume (EDV), LV end-systolic volume (ESV), and LV ejection fraction (EF), evaluated with respect to both absolute and relative differences. For cine CMR, nnU-Net and comDL achieve Dice's coefficients above 0.95 for LV and 0.9 for MYO, and RV. For real-time CMR, the accuracy of nnU-Net exceeds that of comDL overall. For real-time CMR at rest, nnU-Net achieves Dice's coefficients of 0.94 for LV, 0.89 for MYO, and 0.90 for RV and the mean absolute differences between nnU-Net and the reference are 2.9 mL for EDV, 3.5 mL for ESV, and 2.6% for EF. For real-time CMR under exercise stress, nnU-Net achieves Dice's coefficients of 0.92 for LV, 0.85 for MYO, and 0.83 for RV and the mean absolute differences between nnU-Net and reference are 11.4 mL for EDV, 2.9 mL for ESV, and 3.6% for EF. Deep learning methods designed or trained for cine CMR segmentation can perform well on real-time CMR. For real-time free-breathing CMR at rest, the performance of deep learning methods is comparable to inter-observer variability in cine CMR and is usable for fully automatic segmentation. For real-time CMR under exercise stress, the performance of nnU-Net could promise a higher degree of automation in the future.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.