Evidence map›Paper›PMID 38354051›Full record

ArticleAnalytical chemistry2024

Pt-Black-Modified (Hemi)spherical AFM Sensors:

Andreas Hellmann, Gregor Neusser, Sven Daboss, Mohamed M Elnagar, Johannes Liessem, Dariusz Mitoraj, Radim Beranek, Stéphane Arbault, Christine Kranz

Open access · hybridAbstract read
In one paragraph

Article in Analytical chemistry, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.5field-weighted citation impact, top 47% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 3 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 2 institutions in 2 countries.

Andreas HellmannInstitute of Analytical and Bioanalytical Chemistry, Ulm University, Albert-Einstein-Allee 11, 89081 Ulm, Germany.
Gregor NeusserInstitute of Analytical and Bioanalytical Chemistry, Ulm University, Albert-Einstein-Allee 11, 89081 Ulm, Germany.
Sven DabossInstitute of Analytical and Bioanalytical Chemistry, Ulm University, Albert-Einstein-Allee 11, 89081 Ulm, Germany.
Mohamed M ElnagarInstitute of Electrochemistry, Ulm University, Albert-Einstein-Allee 47, 89081 Ulm, Germany.
Johannes LiessemInstitute of Electrochemistry, Ulm University, Albert-Einstein-Allee 47, 89081 Ulm, Germany.
Dariusz MitorajInstitute of Electrochemistry, Ulm University, Albert-Einstein-Allee 47, 89081 Ulm, Germany.
Radim BeranekInstitute of Electrochemistry, Ulm University, Albert-Einstein-Allee 47, 89081 Ulm, Germany.ORCID 0000-0002-7926-0774
Stéphane ArbaultUniv. Bordeaux, CNRS, Bordeaux INP, UMR 5248, CBMN, F-33600 Pessac, France.ORCID 0000-0002-4994-2213
Christine KranzInstitute of Analytical and Bioanalytical Chemistry, Ulm University, Albert-Einstein-Allee 11, 89081 Ulm, Germany.ORCID 0000-0002-6001-0580
Universität Ulm · DECentre National de la Recherche Scientifique · FR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

In this work, we present (hemi)spherical atomic force microscopy (AFM) sensors for the detection of hydrogen peroxide. Platinum-black (Pt-B) was electrodeposited onto conductive colloidal AFM probes or directly at recessed microelectrodes located at the end of a tipless cantilever, resulting in electrocatalytically active cantilever-based sensors that have a small geometric area but, due to the porosity of the films, exhibit a large electroactive surface area. Focused ion beam-scanning electron microscopy tomography revealed the porous 3D structure of the deposited Pt-B. Given the accurate positioning capability of AFM, these probes are suitable for local in situ sensing of hydrogen peroxide and at the same time can be used for (electrochemical) force spectroscopy measurements. Detection limits for hydrogen peroxide in the nanomolar range (LOD = 68 ± 7 nM) were obtained. Stability test and first in situ proof-of-principle experiments to achieve the electrochemical imaging of hydrogen peroxide generated at a microelectrode and at photocatalytically active structured poly(heptazine imide) films are demonstrated. Force spectroscopic data of the photocatalyst films were recorded in ambient conditions, in solution, and by applying a potential, which demonstrates the versatility of these novel Pt-B-modified spherical AFM probes.

Identifiers

PMID38354051
PMCPMC10902814
OpenAlexW4391809365

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.