Evidence map›Paper›PMID 38349537›Full record

ArticleDie Anaesthesiologie2024

Electricity consumption of anesthesia workstations and potential emission savings by avoiding standby.

Hendrik Drinhaus, Jorrit Drinhaus, Christine Schumacher, Michael J Schramm, Wolfgang A Wetsch

Abstract read
In one paragraph

Article in Die Anaesthesiologie, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Hendrik DrinhausFaculty of Medicine and University Hospital of Cologne, Department of Anesthesiology and Intensive Care Medicine, University of Cologne, Kerpener Str. 62, 50937, Cologne, Germany. hendrik.drinhaus@uk-koeln.de.ORCID 0000-0001-8435-2246
Jorrit Drinhaus, 50937, Cologne, Germany.ORCID 0000-0002-7204-5932
Christine SchumacherFaculty of Medicine and University Hospital of Cologne, Department of Anesthesiology and Intensive Care Medicine, University of Cologne, Kerpener Str. 62, 50937, Cologne, Germany.
Michael J SchrammFaculty of Medicine and University Hospital of Cologne, Department of Anesthesiology and Intensive Care Medicine, University of Cologne, Kerpener Str. 62, 50937, Cologne, Germany.
Wolfgang A WetschFaculty of Medicine and University Hospital of Cologne, Department of Anesthesiology and Intensive Care Medicine, University of Cologne, Kerpener Str. 62, 50937, Cologne, Germany.ORCID 0000-0001-5800-6665

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundAnesthesiology has a relevant carbon footprint, mainly due to volatile anesthetics (scope 1 emissions). Additionally, energy used in the operating theater (scope 2 emissions) contributes to anesthesia-related greenhouse gas (GHG) emissions.

objectivesOptimizing the electricity use of medical devices might reduce both GHG emissions and costs might hold potential to reduce anaesthesia-related GHG-emissions and costs. We analyzed the electricity consumption of six different anesthesia workstations, calculated their GHG emissions and electricity costs and investigated the potential to reduce emissions and cost by using the devices in a more efficient way.

methodsPower consumption (active power in watt , W) was measured with the devices off, in standby mode, or fully on with the measuring instrument SecuLife ST. Devices studied were: Dräger Primus, Löwenstein Medical LeonPlus, Getinge Flow C, Getinge Flow E, GE Carestation 750 and GE Aisys. Calculations of GHG emissions were made with different emission factors, ranging from very low (0.09 kg CO

resultsPower consumption during operation varied from 58 W (GE CareStation 750) to 136 W (Dräger Primus). In standby, the devices consumed between 88% and 93% of the electricity needed during use. The annual electricity consumption to run 96 devices in a large clinical department ranges between 45 and 105 Megawatt-hours (MWh) when the devices are left in standby during off hours. If 80% of the devices are switched off during off hours, between 20 and 46 MWh can be saved per year in a single institution. At the average emission factor of our hospital, this electricity saving corresponds to a reduction of GHG emissions between 8.5 and 19.8 tons CO

conclusionThe power consumption varies considerably between the different types of anesthesia workstations. All devices exhibit a high electricity consumption in standby mode. Avoiding standby mode during off hours can save energy and thus GHG emissions and cost. The reductions in GHG emissions and electricity cost that can be achieved with this intervention in a large anesthesiology department are modest. Compared with GHG emissions generated by volatile anesthetics, particularly desflurane, optimization of electricity consumption of anesthesia workstations holds a much smaller potential to reduce the carbon footprint of anesthesia; however, as switching off anesthesia workstations overnight is relatively effortless, this behavioral change should be encouraged from both an ecological and economical point of view.

Indexed as

AnesthesiaAnestheticsGreenhouse GasesCarbon DioxideElectricityAnestheticsCarbon DioxideGreenhouse GasesAnesthesia workstationCarbon footprintClimate changeCost analysisElectricity consumptionElectricity costEnergy saving

Identifiers

PMID38349537
PMCPMC11021308

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.