Evidence map›Paper›PMID 38349454›Full record

ArticleMagma (New York, N.Y.)2024

Linearity and bias of proton density fat fraction across the full dynamic range of 0-100%: a multiplatform, multivendor phantom study using 1.5T and 3T MRI at two sites.

Houchun H Hu, Henry Szu-Meng Chen, Diego Hernando

Abstract readMulticenter Study
In one paragraph

Article in Magma (New York, N.Y.), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Houchun H HuDepartment of Radiology, Section of Radiological Science, Anschutz School of Medicine, University of Colorado Denver, Anschutz Medical Campus, Leprino Building, 12401 E 17th Ave, 5th Floor, Mail Stop L954, Aurora, CO, 80045, USA. houchun.hu@cuanschutz.edu.ORCID http://orcid.org/0000-0002-0719-1159
Henry Szu-Meng ChenDepartment of Radiology, Section of Radiological Science, Anschutz School of Medicine, University of Colorado Denver, Anschutz Medical Campus, Leprino Building, 12401 E 17th Ave, 5th Floor, Mail Stop L954, Aurora, CO, 80045, USA.
Diego HernandoDepartment of Radiology, University of Wisconsin, Madison, WI, USA.

Funding

Fully Automated High-Throughput Quantitative MRI of the LiverR01EB031886 · NIBIB · UNIVERSITY OF WISCONSIN-MADISON · PI HERNANDO, DIEGO, REEDER, SCOTT B. · 2022 to 2025
$2.4M
Quantitative Magnetic Resonance Imaging PhantomsR44EB025729 · NIBIB · CALIMETRIX, LLC · PI BRITTAIN, JEAN H., HERNANDO, DIEGO · 2019 to 2020
$1.5M
Faculty Development Pilot Grant of the Department of Radiology at the University of Colorado, Anschutz Medical Campus RADFDG-0002NIBIB NIH HHS R01 EB031886NIBIB NIH HHS R44 EB025729NIH HHS R01EB031886NIH HHS R44EB025729
6 · The paper itself

Abstract

objectivePerformance assessments of quantitative determinations of proton density fat fraction (PDFF) have largely focused on the range between 0 and 50%. We evaluate PDFF in a two-site phantom study across the full 0-100% PDFF range. MATERIALS AND

methodsWe used commercially available 3D chemical-shift-encoded water-fat MRI sequences from three MRI system vendors at 1.5T and 3T and conducted the study across two sites. A spherical phantom housing 18 vials spanning the full 0-100% PDFF range was used. Data at each site were acquired using default parameters to determine same-day and different-day intra-scanner repeatability, and inter-system and inter-site reproducibility, in addition to linear regression between reference and measured PDFF values.

resultsAcross all systems, results demonstrated strong linearity and minimal bias. For 1.5T systems, a pooled slope of 0.99 with a 95% confidence interval (CI) of 0.981-0.997 and a pooled intercept of 0.61% PDFF with a 95% CI of 0.17-1.04 were obtained. Results for pooled 3T data included a slope of 1.00 (95% CI 0.995-1.005) and an intercept of 0.69% PDFF (95% CI 0.39-0.97). Inter-site and inter-system reproducibility coefficients ranged from 2.9 to 6.2 (in units of PDFF), while intra-scanner same-day and different-day repeatability ranged from 0.6 to 7.8. DISCUSSION: PDFF across the 0-100% range can be reliably estimated using current commercial offerings at 1.5T and 3T.

Indexed as

Adipose TissueMagnetic Resonance ImagingPhantoms, ImagingProtonsBiasHumansImage Processing, Computer-AssistedImaging, Three-DimensionalLinear ModelsReproducibility of ResultsProtonsMulti-centerMulti-vendorProton density fat fractionQuantitativeRepeatabilityReproducibility

Identifiers

PMID38349454
PMCPMC11428149

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.