Interfractional variation in whole-breast VMAT irradiation: a dosimetric study with complementary SGRT and CBCT patient setup.

M Mankinen, T Virén, J Seppälä, T Koivumäki

Open access · goldAbstract read
In one paragraph

Article in Radiation oncology (London, England), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed
4.9field-weighted citation impact, top 5% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed, 8 citations in OpenAlex.

  1. Trial
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 2 institutions in 1 country.

M MankinenDeparment of Physics, University of Jyväskylä (JYU), Survontie 9 C, 40014, Jyväskylä, Finland. mikko.m.mankinen@student.jyu.fi.
T VirénCenter of Oncology, Kuopio University Hospital (KUH), The Wellbeing Services Country of North Savo, Kuopio, Finland.
J SeppäläCenter of Oncology, Kuopio University Hospital (KUH), The Wellbeing Services Country of North Savo, Kuopio, Finland.
T KoivumäkiDeparment of Physics, University of Jyväskylä (JYU), Survontie 9 C, 40014, Jyväskylä, Finland.
Kuopio University Hospital · FIUniversity of Jyväskylä · FI

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe dosimetric effect of setup uncertainty and tissue deformations in left-sided whole-breast irradiation with complementary surface-guided radiotherapy (SGRT) and cone-beam computed tomography (CBCT) setup was evaluated.

methodTreatment courses of 40.05 Gy prescribed dose in 15 fractions were simulated for 29 patients by calculating the dose on deformed CT images, that were based on daily CBCT images, and deforming and accumulating the dose onto the planning CT image. Variability in clinical target volume (CTV) position and shape was assessed as the 95% Hausdorff distance (HD95) between the planning CTV and deformed CTV structures. DVH metrics were evaluated between the planned and simulated cumulative dose distributions using two treatment techniques: tangential volumetric modulated arc therapy (tVMAT) and conventional 3D-conformal radiotherapy (3D-CRT).

resultsBased on the HD95 values, the variations in CTV shape and position were enclosed by the 5 mm CTV-PTV margin in 85% of treatment fractions using complementary CBCT and SGRT setup. A residual error of 8.6 mm was observed between the initial SGRT setup and CBCT setup. The median CTV V95% coverage was 98.1% (range 93.1-99.8%) with tVMAT and 98.2% (range 84.5-99.7%) with 3D-CRT techniques with CBCT setup. With the initial SGRT-only setup, the corresponding coverages were 96.3% (range 92.6-99.4%) and 96.6% (range 84.2-99.4%), respectively. However, a considerable bias in vertical residual error between initial SGRT setup and CBCT setup was observed. Clinically relevant changes between the planned and cumulative doses to organs-at-risk (OARs) were not observed.

conclusionsThe CTV-to-PTV margin should not be reduced below 5 mm even with daily CBCT setup. Both tVMAT and 3D-CRT techniques were robust in terms of dose coverage to the target and OARs. Based on the shifts between setup methods, CBCT setup is recommended as a complementary method with SGRT.

Indexed as

Radiotherapy, ConformalRadiotherapy, Image-GuidedRadiotherapy, Intensity-ModulatedSpiral Cone-Beam Computed TomographyCone-Beam Computed TomographyHumansRadiotherapy DosageRadiotherapy Planning, Computer-AssistedCBCTSetup marginSetup uncertaintyTissue deformationsVMAT

Identifiers

PMID38347554
PMCPMC10863193
OpenAlexW4391784344

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.