Evidence map›Paper›PMID 38345816›Full record

ArticleJAMA network open2024

Artificial Intelligence Assistive Software Tool for Automated Detection and Quantification of Amyloid-Related Imaging Abnormalities.

Diana M Sima, Thanh Vân Phan, Simon Van Eyndhoven, Sophie Vercruyssen, Ricardo Magalhães, Arno Liseune, Arne Brys, Peter Frenyo, Vasilis Terzopoulos, Celine Maes and 11 more

Open access · goldAbstract read
In one paragraph

Article in JAMA network open, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 19 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
19citing papers in PubMed, 1 pooled it
12.3field-weighted citation impact, top 1% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

19 citing papers in PubMed, 1 synthesis or guideline pooled it, 32 citations in OpenAlex.

  1. Pooled it
  2. Integrating Anatomical Priors Into a Causal Diffusion Model.IEEE transactions on medical imaging · 2026
    Article
  3. Article
  4. Observational
  5. Article
  6. Review
  7. Article
  8. Review
  9. Article
  10. Review
  11. Review
  12. Review
  13. Review
  14. Article
  15. Review
  16. Review
  17. Review
  18. Article
  19. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

21 authors at 2 institutions in 2 countries.

Diana M Simaicometrix, Leuven, Belgium.
Thanh Vân Phanicometrix, Leuven, Belgium.
Simon Van Eyndhovenicometrix, Leuven, Belgium.
Sophie Vercruyssenicometrix, Leuven, Belgium.
Ricardo Magalhãesicometrix, Leuven, Belgium.
Arno Liseuneicometrix, Leuven, Belgium.
Arne Brysicometrix, Leuven, Belgium.
Peter Frenyoicometrix, Leuven, Belgium.
Vasilis Terzopoulosicometrix, Leuven, Belgium.
Celine Maesicometrix, Leuven, Belgium.
Joshua GuoBiogen Digital Health, Biogen, Cambridge, Massachusetts.
Richard HughesBiogen Digital Health, Biogen, Cambridge, Massachusetts.
Refaat E GabrBiogen Digital Health, Biogen, Cambridge, Massachusetts.
Willem HuijbersBiogen Digital Health, Biogen, Cambridge, Massachusetts.
Paramita Saha-ChaudhuriBiogen Digital Health, Biogen, Cambridge, Massachusetts.
Gioacchino G CurialeBiogen, Cambridge, Massachusetts.
Andrew BeckerBiogen Digital Health, Biogen, Cambridge, Massachusetts.
Shibeshih BelachewBiogen Digital Health, Biogen, Cambridge, Massachusetts.
Wim Van Heckeicometrix, Leuven, Belgium.
Annemie Ribbensicometrix, Leuven, Belgium.
Dirk Smeetsicometrix, Leuven, Belgium.
Icometrix (Belgium) · BEBiogen (United States) · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Importance: Amyloid-related imaging abnormalities (ARIA) are brain magnetic resonance imaging (MRI) findings associated with the use of amyloid-β-directed monoclonal antibody therapies in Alzheimer disease (AD). ARIA monitoring is important to inform treatment dosing decisions and might be improved through assistive software. Objective: To assess the clinical performance of an artificial intelligence (AI)-based software tool for assisting radiological interpretation of brain MRI scans in patients monitored for ARIA. Design, Setting, and Participants: This diagnostic study used a multiple-reader multiple-case design to evaluate the diagnostic performance of radiologists assisted by the software vs unassisted. The study enrolled 16 US Board of Radiology-certified radiologists to perform radiological reading with (assisted) and without the software (unassisted). The study encompassed 199 retrospective cases, where each case consisted of a predosing baseline and a postdosing follow-up MRI of patients from aducanumab clinical trials PRIME, EMERGE, and ENGAGE. Statistical analysis was performed from April to July 2023. Exposures: Use of icobrain aria, an AI-based assistive software for ARIA detection and quantification. Main Outcomes and Measures: Coprimary end points were the difference in diagnostic accuracy between assisted and unassisted detection of ARIA-E (edema and/or sulcal effusion) and ARIA-H (microhemorrhage and/or superficial siderosis) independently, assessed with the area under the receiver operating characteristic curve (AUC). Results: Among the 199 participants included in this study of radiological reading performance, mean (SD) age was 70.4 (7.2) years; 105 (52.8%) were female; 23 (11.6%) were Asian, 1 (0.5%) was Black, 157 (78.9%) were White, and 18 (9.0%) were other or unreported race and ethnicity. Among the 16 radiological readers included, 2 were specialized neuroradiologists (12.5%), 11 were male individuals (68.8%), 7 were individuals working in academic hospitals (43.8%), and they had a mean (SD) of 9.5 (5.1) years of experience. Radiologists assisted by the software were significantly superior in detecting ARIA than unassisted radiologists, with a mean assisted AUC of 0.87 (95% CI, 0.84-0.91) for ARIA-E detection (AUC improvement of 0.05 [95% CI, 0.02-0.08]; P = .001]) and 0.83 (95% CI, 0.78-0.87) for ARIA-H detection (AUC improvement of 0.04 [95% CI, 0.02-0.07]; P = .001). Sensitivity was significantly higher in assisted reading compared with unassisted reading (87% vs 71% for ARIA-E detection; 79% vs 69% for ARIA-H detection), while specificity remained above 80% for the detection of both ARIA types. Conclusions and Relevance: This diagnostic study found that radiological reading performance for ARIA detection and diagnosis was significantly better when using the AI-based assistive software. Hence, the software has the potential to be a clinically important tool to improve safety monitoring and management of patients with AD treated with amyloid-β-directed monoclonal antibody therapies.

Indexed as

Alzheimer DiseaseArtificial IntelligenceAgedAmyloidAmyloid beta-PeptidesAntibodies, MonoclonalFemaleHumansMaleRetrospective StudiesSoftwareAmyloidAmyloid beta-PeptidesAntibodies, Monoclonal

Identifiers

PMID38345816
PMCPMC10862143
OpenAlexW4391744496

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.