Evidence map›Paper›PMID 38345661›Full record

ArticleThe Egyptian heart journal : (EHJ) : official bulletin of the Egyptian Society of Cardiology2024

Impact of prosthesis oversizing on clinical outcomes of transcatheter aortic valve implantation using a self-expandable Evolut R valve.

Mohammed Moustafa Elnwagy, Mahmoud Mohamed Ali Baraka, Mohamed Saber Hafez, Diaa Kamal, Maiy Hamdy El-Sayed, Ahmad E Mostafa

Open access · diamondAbstract read
In one paragraph

Article in The Egyptian heart journal : (EHJ) : official bulletin of the Egyptian Society of Cardiology, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
2.4field-weighted citation impact, top 11% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 6 citations in OpenAlex.

  1. Annular Ellipticity and Sizing Strategy in Transcatheter Aortic Valve Implantation: Independent or Combined Risk Patterns?Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions · 2026
    Article
  2. Article
  3. Article
  4. Observational
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 1 country.

Mohammed Moustafa ElnwagyCardiology department, Ain Shams University, Abbassya, P0 11591, Cairo, Egypt. m.moustafa.asu@gmail.com.ORCID http://orcid.org/0000-0002-6192-2434
Mahmoud Mohamed Ali BarakaCardiology department, Ain Shams University, Abbassya, P0 11591, Cairo, Egypt.
Mohamed Saber HafezCardiology department, Ain Shams University, Abbassya, P0 11591, Cairo, Egypt.
Diaa KamalCardiology department, Ain Shams University, Abbassya, P0 11591, Cairo, Egypt.
Maiy Hamdy El-SayedCardiology department, Ain Shams University, Abbassya, P0 11591, Cairo, Egypt.
Ahmad E MostafaCardiology department, Ain Shams University, Abbassya, P0 11591, Cairo, Egypt.
Ain Shams University · EG

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundTranscatheter Aortic Valve Implantation (TAVI) has a growing target population after being indicated even in low-surgical-risk patients with severe symptomatic aortic stenosis. However, postoperative outcomes can be compromised due to para-valvular leakage (PVL). A lot of procedural steps have been investigated to decrease this partially avoidable operational hazard. Oversizing is a main technique to decrease the PVL, despite being itself a risky step. Many studies have been conducted to identify the optimum degree of oversizing. However, studies about oversizing by more than 20% are scarce. We aimed to evaluate the safety and efficacy of oversizing equal to or more than 20%.

results209 patients who underwent TAVI using the self-expandable valve Evolut R were initially included. 66 patients were excluded because of the baseline conduction disturbance and lack of sufficient data, so 143 patients, 60 females and 83 males, were enrolled in our study as two groups based on the degree of oversizing: Group A included 97 patients with an oversizing index (OI) of less than 20%, and Group B included 46 patients with an OI of 20% or more. We conducted a new technique for more accurate measuring of the OI in the context of the implantation depth, and our patients were categorized using this technique. Our findings have met our primary end point in terms of the safety and efficacy of oversizing by 20% or more. There was no significant difference between both groups in terms of new-onset conduction disturbance (NOCD), with zero cases of annular rupture or coronary encroachment. In terms of efficacy, The incidence of significant PVL (grade 2 or more) in group B was less than in group A (P value 0.007). The ROC curve found that the minimum depth of implantation-derived oversizing (DIDO) to predict no significant PVL was less than 17%.

conclusionProsthesis oversizing by 20% using the self-expandable Evolut R valve is safe and effective, with no significant effect on the conduction system, coronary encroachment, or annular injury, and warrants a greater reduction in the incidence of significant PVL.

Indexed as

Anscatheter aortic valve implantationOversizing indexPara-valvular leakage

Identifiers

PMID38345661
PMCPMC10861408
OpenAlexW4391744346

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.