Microchip Versus Piezoelectric Point of Care Ultrasonography for Pulmonary and Vena Cava Evaluation in Patients With Acute Kidney Injury.

Débora Miguel Soares, Renata de Souza Mendes, José Hermógenes Rocco Suassuna

Open access · goldAbstract read
In one paragraph

Article in Kidney international reports, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
0.2field-weighted citation impact, top 44% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 1 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 2 institutions in 1 country.

Débora Miguel SoaresClinical and Academic Unit of Nephrology, Hospital Universitário Pedro Ernesto, Faculty of Medical Sciences, Rio de Janeiro State University, Maracanã, Rio de Janeiro, Brazil.
Renata de Souza MendesClinical and Academic Unit of Nephrology, Hospital Universitário Pedro Ernesto, Faculty of Medical Sciences, Rio de Janeiro State University, Maracanã, Rio de Janeiro, Brazil.
José Hermógenes Rocco SuassunaClinical and Academic Unit of Nephrology, Hospital Universitário Pedro Ernesto, Faculty of Medical Sciences, Rio de Janeiro State University, Maracanã, Rio de Janeiro, Brazil.
Hospital Universitário Pedro Ernesto · BRUniversidade do Estado do Rio de Janeiro · BR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Introduction: Point-of-care ultrasonography (POCUS) has emerged as an important tool for examining critically ill patients. POCUS devices have become progressively smaller and more accessible, transforming medical practice, and reducing costs. One technological breakthrough was the development of ultraportable scanners with microchip technology, which utilize a probe connected to a smartphone or tablet and incorporate a mobile application that employs artificial intelligence to assist in the interpretation of acquired images. The aim of this study was to compare the accuracy of ultrasound microchip technology with traditional piezoelectric crystal ultrasonography. We analyzed 2 volume status parameters in intensive care unit (ICU) patients with acute kidney injury (AKI) who were receiving kidney replacement therapy (KRT). These parameters were the extravascular pulmonary water, using the lung B-lines; and the inferior vena cava collapsibility index (IVCi). Methods: Fifty critically ill patients met the study criteria. Lung POCUS quantified B-lines in 8 quadrants. The IVCi was measured using the maximum and minimum diameters during a respiratory cycle. Both technologies were sequentially employed in a randomized fashion to acquire the parameters at 2 different time points: before the initiation of KRT (T0) and 60 minutes after the procedure had commenced (T60). We calculated the correlation and agreement between the 2 ultrasound scanner modalities. Results: The correlation between the 2 technologies for evaluating lung B-lines showed strong positive coefficients, ⍴ = 0.96 and ⍴ = 0.93 at T0 and T60, respectively ( Conclusion: Our study observed a good correlation and agreement between microchip and piezoelectric-based ultrasound modalities in evaluating the presence of pulmonary B-lines and inferior vena cava (IVC) dynamics in patients with AKI. Microchip ultrasound, in addition to being portable, user-friendly, and cost-effective, consistently delivers bedside parameters for volume assessment that are comparable to those obtained through POCUS using piezoelectric transducer-based ultrasonography.

Indexed as

acute kidney injurypoint-of-care ultrasonography

Identifiers

PMID38344740
PMCPMC10851012
OpenAlexW4389010085

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.