ArticleMicrochemical journal : devoted to the application of microtechniques in all branches of science2023
An Integrated Approach to Improve the Assay Performance of Quantum Dot-Based Lateral Flow Immunoassays by Using Silver Deposition.
Article in Microchemical journal : devoted to the application of microtechniques in all branches of science, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
3 citing papers in PubMed.
- Lateral Flow Immunochromatographic Assay for Detection of Antibodies Against a Recombinant Human Adenovirus Type 3 Hexon Fragment Using Gold Nanoparticles and Quantum Dots.Diagnostics (Basel, Switzerland) · 2026Article
- Wearable sensors: in situ detection tools for plant physiological markers and growth environment information.Mikrochimica acta · 2025Review
- Post-Assay Chemical Enhancement for Highly Sensitive Lateral Flow Immunoassays: A Critical Review.Biosensors · 2023Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
Abstract
Traditional quantum dot-based lateral flow immunoassay (QD-LFIA) is limited to signal loss in part by the blinking, photobleaching and oxidative quenching of QD probes. Inspired by the good application of silver deposition on QD surfaces in tissue imaging, and in the context of improving the assay performance without compromising the simplicity and practicality, we report that introducing the QD-silver combination to the LFIA system, has the advantages of accuracy improvement, signal enhancement and user friendliness promotion, but maintains the cost-effective property and commercial accessibility of QD-LFIA. The effect was shown by using CdSe/ZnS QD-LFIA coupled with anti-sodium pentachlorophenate antibody, which provided a 4-fold improvement in the signal, a 2.5-fold improvement in the detection limit and a zero false-negative rate for sodium pentachlorophenate analysis in chicken samples. The proposed LFIA integrates the possibilities of colorimetric and fluorometric detection with different detection limits (fluorometric at 10 ng/mL and colorimetric at 4 ng/mL) and with acceptable detection times (fluorometric at 12 min and colorimetric at 27 min). The current results indicate that this QD-silver combined LFIA is complementary to conventional fluorescence LFIA and could be an inexpensive, versatile, and sensitive alternative.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.