Evidence map›Paper›PMID 38344059›Full record

ArticleNuclear instruments & methods in physics research. Section B, Beam interactions with materials and atoms2021

Conversion of the LLNL/CAMS 1 MV biological AMS system to a semi-automated natural abundance

Taylor A B Broek, Ted J Ognibene, Karis J McFarlane, Kimber C Moreland, Tom A Brown, Graham Bench

Abstract read
In one paragraph

Article in Nuclear instruments & methods in physics research. Section B, Beam interactions with materials and atoms, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Optimization of the LLNL/CAMS gas-accepting ion source and 1 MV compact AMS for natural abundance radiocarbon analysis of CONuclear instruments & methods in physics research. Section B, Beam interactions with materials and atoms · 2022
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Taylor A B BroekLawrence Livermore National Laboratory Center for Accelerator Mass Spectrometry, 7000 East Avenue, L-397, Livermore, CA 94550, USA.
Ted J OgnibeneLawrence Livermore National Laboratory Center for Accelerator Mass Spectrometry, 7000 East Avenue, L-397, Livermore, CA 94550, USA.
Karis J McFarlaneLawrence Livermore National Laboratory Center for Accelerator Mass Spectrometry, 7000 East Avenue, L-397, Livermore, CA 94550, USA.
Kimber C MorelandLawrence Livermore National Laboratory Center for Accelerator Mass Spectrometry, 7000 East Avenue, L-397, Livermore, CA 94550, USA.
Tom A BrownLawrence Livermore National Laboratory Center for Accelerator Mass Spectrometry, 7000 East Avenue, L-397, Livermore, CA 94550, USA.
Graham BenchLawrence Livermore National Laboratory Center for Accelerator Mass Spectrometry, 7000 East Avenue, L-397, Livermore, CA 94550, USA.

Funding

VITAMIN C (ASCORBATE) METABOLISM IN DROSPHILA MELANOGASTERP41RR013461 · NCRR · UNIVERSITY OF CALIF-LAWRNC LVRMR NAT LAB · PI ALLEN, LINDSAY H · 1999 to 2011
$20.8M
Resource for the Development of Biomedical Accelerator Mass Spectrometry (AMS)P41GM103483 · NIGMS · UNIVERSITY OF CALIF-LAWRNC LVRMR NAT LAB · PI TURTELTAUB, KENNETH W. · 2012 to 2019
$12.0M
National User Resource for Biological Accelerator Mass SpectrometryR24GM137748 · NIGMS · LAWRENCE LIVERMORE NATIONAL SECURITY, LLC · PI BENCH, GRAHAM · 2020 to 2024
$6.5M
NCRR NIH HHS P41 RR013461NIGMS NIH HHS P41 GM103483NIGMS NIH HHS R24 GM137748
6 · The paper itself

Abstract

The Lawrence Livermore National Laboratory - Center for Accelerator Mass Spectrometry compact 1 MV biomedical accelerator mass spectrometer was repurposed and optimized for the semi-automated radiocarbon measurement of natural abundance environmental samples. Substantial efforts were made to greatly improve instrument precision and develop semi-automation capabilities for unattended operation. Here we present results from 15 months of routine system operation and evaluate the system performance based on 30 sample wheels measured with directly comparable operating conditions over 7 months from August 2019 to March 2020. Unattended operation was enabled through software that tracks specific error conditions and can initiate a complete instrument shutdown when specific criteria were met. The average measurement precision was found to be 2.7 ± 0.7 ‰ based on repeated measurements of OX I standards. Accuracy was assessed with measurements of standard materials with known

Indexed as

Accelerator Mass SpectrometryRadiocarbon

Identifiers

PMID38344059
PMCPMC10854407

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.