Evidence map›Paper›PMID 38343511›Full record

ArticleAnnals of pediatric cardiology

Off-label use of KONAR-MF™ occluder for transcatheter closure of patent ductus arteriosus in unusual circumstances.

Ashishkumar Banpurkar, Nageswara Rao Koneti, Prashant Thakur, Snehal M Kulkarni, Atul Prabhu, Pavan Kumar Venkata Doniparti

Open access · diamondAbstract read
In one paragraph

Article in Annals of pediatric cardiology. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
1.5field-weighted citation impact, top 16% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 7 citations in OpenAlex.

  1. Article
  2. Transcatheter patent ductus arteriosus closure with KONAR-MF occluder in an 80-year-old patient.Postepy w kardiologii interwencyjnej = Advances in interventional cardiology · 2026
    Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 1 country.

Ashishkumar BanpurkarDepartment of Pediatric Cardiology, Sri Sathya Sai Sanjeevani Centre for Child Heart Care, Navi Mumbai, Maharashtra, India.
Nageswara Rao KonetiDepartment of Pediatric Cardiology, Rainbow Children's Heart Institute, Hyderabad, Telangana, India.
Prashant ThakurDepartment of Pediatric Cardiology, Sri Sathya Sai Sanjeevani Center for Child Heart Care, Chhattisgarh, India.
Snehal M KulkarniDepartment of Pediatric Cardiology, Sri Sathya Sai Sanjeevani Centre for Child Heart Care, Navi Mumbai, Maharashtra, India.
Atul PrabhuDepartment of Pediatric Cardiology, Sri Sathya Sai Sanjeevani Center for Child Heart Care, Chhattisgarh, India.
Pavan Kumar Venkata DonipartiDepartment of Pediatric Cardiology, Rainbow Children's Heart Institute, Hyderabad, Telangana, India.
Rainbow Children's Hospital · IN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Transcatheter patent ductus arteriosus (PDA) closure with unusual morphology associated with multiple constrictions or unusual circumstances such as interruption of inferior vena cava (IVC) is still challenging. This study evaluates the use of KONAR-MF™ (Lifetech Scientific Co Ltd., Shenzhen) for transcatheter closure of PDA in such situations. Materials and Methods and Results: Between January 2021 and October 2021, 24 patients from three different tertiary care centers underwent PDA device closure using the KONAR-MF™ device and are included in the study. Patient demographics, echocardiographic assessment, procedural details including the approach, device details, complications, and follow-up data were recorded. The median age and weight of the cohort were 2 years (0.5-41) and 10 kg (5-98), respectively. The indications for using KONAR-MF™ were (a) unusual morphology of PDA in 14, long tubular PDA in 8, and long tubular with multiple constrictions in 6 patients and (b) unusual circumstances such as interrupted IVC in 6 and inability to cross PDA antegradely in 4 due to dilated main pulmonary artery. The procedure was successful in all the patients and no procedure-related complications were noted in this cohort. Median follow-up of 9 months (range: 5-18) showed no residual shunt and only one patient had flow acceleration across the left pulmonary artery (peak Doppler gradient 16 mmHg). Conclusions: KONAR-MF™ device can be used safely and effectively for transcatheter closure of PDA with unusual anatomy or in unusual circumstances.

Indexed as

Duct occluderinterrupted inferior vena cavaKONAR-MF™patent ductus arteriosustranscatheter closure

Identifiers

PMID38343511
PMCPMC10856615
OpenAlexW4390622691

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-SA
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.