Evidence map›Paper›PMID 38343252›Full record

ArticleJournal of imaging informatics in medicine2024

Multiple Kernel Synthesis of Head CT Using a Task-Based Loss Function.

Brandon J Nelson, Daniel G Gomez-Cardona, Jamison E Thorne, Nathan R Huber, Lifeng Yu, Shuai Leng, Cynthia H McCollough, Andrew D Missert

Abstract read
In one paragraph

Article in Journal of imaging informatics in medicine, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. State-of-the-Art Deep Learning CT Reconstruction Algorithms in Abdominal Imaging.Radiographics : a review publication of the Radiological Society of North America, Inc · 2024
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Brandon J Nelson *Department of Radiology, Mayo Clinic, 200 First Street SW, 55905, Rochester, MN, USA.
Daniel G Gomez-Cardona *Department of Radiology, Mayo Clinic, 200 First Street SW, 55905, Rochester, MN, USA.
Jamison E ThorneDepartment of Radiology, Mayo Clinic, 200 First Street SW, 55905, Rochester, MN, USA.
Nathan R HuberDepartment of Radiology, Mayo Clinic, 200 First Street SW, 55905, Rochester, MN, USA.
Lifeng YuDepartment of Radiology, Mayo Clinic, 200 First Street SW, 55905, Rochester, MN, USA.
Shuai LengDepartment of Radiology, Mayo Clinic, 200 First Street SW, 55905, Rochester, MN, USA.
Cynthia H McColloughDepartment of Radiology, Mayo Clinic, 200 First Street SW, 55905, Rochester, MN, USA.
Andrew D MissertDepartment of Radiology, Mayo Clinic, 200 First Street SW, 55905, Rochester, MN, USA. missert.andrew@mayo.edu.ORCID 0000-0002-2825-696X

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

In CT imaging of the head, multiple image series are routinely reconstructed with different kernels and slice thicknesses. Reviewing the redundant information is an inefficient process for radiologists. We address this issue with a convolutional neural network (CNN)-based technique, synthesiZed Improved Resolution and Concurrent nOise reductioN (ZIRCON), that creates a single, thin, low-noise series that combines the favorable features from smooth and sharp head kernels. ZIRCON uses a CNN model with an autoencoder U-Net architecture that accepts two input channels (smooth- and sharp-kernel CT images) and combines their salient features to produce a single CT image. Image quality requirements are built into a task-based loss function with a smooth and sharp loss terms specific to anatomical regions. The model is trained using supervised learning with paired routine-dose clinical non-contrast head CT images as training targets and simulated low-dose (25%) images as training inputs. One hundred unique de-identified clinical exams were used for training, ten for validation, and ten for testing. Visual comparisons and contrast measurements of ZIRCON revealed that thinner slices and the smooth-kernel loss function improved gray-white matter contrast. Combined with lower noise, this increased visibility of small soft-tissue features that would be otherwise impaired by partial volume averaging or noise. Line profile analysis showed that ZIRCON images largely retained sharpness compared to the sharp-kernel input images. ZIRCON combined desirable image quality properties of both smooth and sharp input kernels into a single, thin, low-noise series suitable for both brain and skull imaging.

Indexed as

HeadImage Processing, Computer-AssistedNeural Networks, ComputerTomography, X-Ray ComputedHumansCNNCTDenoisingHeadLoss functionNeuro

Identifiers

PMID38343252
PMCPMC11589061

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.