Evidence map›Paper›PMID 38343222›Full record

ArticleJournal of imaging informatics in medicine2024

Automatic Urinary Stone Detection System for Abdominal Non-Enhanced CT Images Reduces the Burden on Radiologists.

Zhaoyu Xing, Zuhui Zhu, Zhenxing Jiang, Jingshi Zhao, Qin Chen, Wei Xing, Liang Pan, Yan Zeng, Aie Liu, Jiule Ding

Open access · greenAbstract read
In one paragraph

Article in Journal of imaging informatics in medicine, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
1.3field-weighted citation impact, top 22% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 3 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors at 4 institutions in 1 country.

Zhaoyu Xing *Department of Urology, Third Affiliated Hospital of Soochow University, Changzhou, Jiangsu, China.
Zuhui Zhu *Department of Radiology, Nantong Hospital of Traditional Chinese Medicine, Nantong, Jiangsu, China.
Zhenxing JiangDepartment of Radiology, Third Affiliated Hospital of Soochow University, Changzhou, Jiangsu, China.
Jingshi ZhaoDepartment of Radiology, Fourth Affiliated Hospital of Harbin Medical University, Harbin, China.
Qin ChenDepartment of Radiology, People's Hospital of Pengzhou, Chengdu, Sichuan, China.
Wei XingDepartment of Radiology, Third Affiliated Hospital of Soochow University, Changzhou, Jiangsu, China.
Liang PanDepartment of Radiology, Third Affiliated Hospital of Soochow University, Changzhou, Jiangsu, China.
Yan ZengDepartment of Research Center, Shanghai United Imaging Intelligence Co. Ltd, Shanghai, China. yan.zeng@uii-ai.com.
Aie LiuDepartment of Research Center, Shanghai United Imaging Intelligence Co. Ltd, Shanghai, China. aie.liu@uii-ai.com.
Jiule DingDepartment of Radiology, Third Affiliated Hospital of Soochow University, Changzhou, Jiangsu, China. dingjiule@163.com.ORCID 0000-0001-8945-4807
Soochow University · CNUnited Imaging Healthcare (China) · CNAnyang Hospital of Traditional Chinese Medicine · CNHarbin Medical University · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

To develop a fully automatic urinary stone detection system (kidney, ureter, and bladder) and to test it in a real clinical environment. The local institutional review board approved this retrospective single-center study that used non-enhanced abdominopelvic CT scans from patients admitted urology (uPatients) and emergency (ePatients). The uPatients were randomly divided into training and validation sets in a ratio of 3:1. We designed a cascade urinary stone map location-feature pyramid networks (USm-FPNs) and innovatively proposed a ureter distance heatmap method to estimate the ureter position on non-enhanced CT to further reduce the false positives. The performances of the system were compared using the free-response receiver operating characteristic curve and the precision-recall curve. This study included 811 uPatients and 356 ePatients. At stone level, the cascade detector USm-FPNs has the mean of false positives per scan (mFP) 1.88 with the sensitivity 0.977 in validation set, and mFP was further reduced to 1.18 with the sensitivity 0.977 after combining the ureter distance heatmap. At patient level, the sensitivity and precision were as high as 0.995 and 0.990 in validation set, respectively. In a real clinical set of ePatients (27.5% of patients contain stones), the mFP was 1.31 with as high as sensitivity 0.977, and the diagnostic time reduced by > 20% with the system help. A fully automatic detection system for entire urinary stones on non-enhanced CT scans was proposed and reduces obviously the burden on junior radiologists without compromising sensitivity in real emergency data.

Indexed as

Radiographic Image Interpretation, Computer-AssistedRadiography, AbdominalTomography, X-Ray ComputedUrinary CalculiAdultAgedFemaleHumansMaleMiddle AgedRetrospective StudiesSensitivity and SpecificityArtificial intelligenceEmergenciesTomographyUrinary calculi

Identifiers

PMID38343222
PMCPMC11031534
OpenAlexW4390708502

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.