Evidence map›Paper›PMID 38343221›Full record

ArticleJournal of imaging informatics in medicine2024

A 3D Sparse Autoencoder for Fully Automated Quality Control of Affine Registrations in Big Data Brain MRI Studies.

Venkata Sainath Gupta Thadikemalla, Niels K Focke, Sudhakar Tummala

Abstract read
In one paragraph

Article in Journal of imaging informatics in medicine, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Venkata Sainath Gupta ThadikemallaDepartment of Electronics and Communication Engineering, Velagapudi Ramakrishna Siddhartha Engineering College, Vijayawada, Andhra Pradesh, India. sainathgupta@vrsiddhartha.ac.in.ORCID 0000-0003-3936-8665
Niels K FockeClinic for Neurology, University Medical Center, Göttingen, Germany.
Sudhakar TummalaDepartment of Electronics and Communication Engineering, School of Engineering and Sciences, SRM University-AP, Andhra Pradesh, India. sudhakar.t@srmap.edu.in.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

This paper presents a fully automated pipeline using a sparse convolutional autoencoder for quality control (QC) of affine registrations in large-scale T1-weighted (T1w) and T2-weighted (T2w) magnetic resonance imaging (MRI) studies. Here, a customized 3D convolutional encoder-decoder (autoencoder) framework is proposed and the network is trained in a fully unsupervised manner. For cross-validating the proposed model, we used 1000 correctly aligned MRI images of the human connectome project young adult (HCP-YA) dataset. We proposed that the quality of the registration is proportional to the reconstruction error of the autoencoder. Further, to make this method applicable to unseen datasets, we have proposed dataset-specific optimal threshold calculation (using the reconstruction error) from ROC analysis that requires a subset of the correctly aligned and artificially generated misalignments specific to that dataset. The calculated optimum threshold is used for testing the quality of remaining affine registrations from the corresponding datasets. The proposed framework was tested on four unseen datasets from autism brain imaging data exchange (ABIDE I, 215 subjects), information eXtraction from images (IXI, 577 subjects), Open Access Series of Imaging Studies (OASIS4, 646 subjects), and "Food and Brain" study (77 subjects). The framework has achieved excellent performance for T1w and T2w affine registrations with an accuracy of 100% for HCP-YA. Further, we evaluated the generality of the model on four unseen datasets and obtained accuracies of 81.81% for ABIDE I (only T1w), 93.45% (T1w) and 81.75% (T2w) for OASIS4, and 92.59% for "Food and Brain" study (only T1w) and in the range 88-97% for IXI (for both T1w and T2w and stratified concerning scanner vendor and magnetic field strengths). Moreover, the real failures from "Food and Brain" and OASIS4 datasets were detected with sensitivities of 100% and 80% for T1w and T2w, respectively. In addition, AUCs of > 0.88 in all scenarios were obtained during threshold calculation on the four test sets.

Indexed as

3D convolutional autoencoderAffine registrationBig dataQuality controlStructural MRI

Identifiers

PMID38343221
PMCPMC10976877

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.