ArticleAdvanced science (Weinheim, Baden-Wurttemberg, Germany)2024

Detection of Blood Clots Using a Whole Stent as an Active Implantable Biosensor.

Mahmut Talha Kirimi, Daniel Hoare, Michael Holsgrove, Jakup Czyzewski, Nosrat Mirzai, John R Mercer, Steve L Neale

Open access · goldAbstract read
In one paragraph

Article in Advanced science (Weinheim, Baden-Wurttemberg, Germany), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
2.9field-weighted citation impact, top 10% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 5 citations in OpenAlex.

  1. Review
  2. Review
  3. Review
  4. Article
  5. Detection of Blood Clots Using a Whole Stent as an Active Implantable Biosensor.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2024
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 2 institutions in 1 country.

Mahmut Talha KirimiCentre for Medical and Industrial Ultrasonics, James Watt School of Engineering, University of Glasgow, Glasgow, G12 8QQ, UK.ORCID 0000-0002-5562-6479
Daniel HoareInstitute of Cardiovascular and Medical Sciences/British Heart Foundation, University of Glasgow, Glasgow, G12 8QQ, UK.ORCID 0000-0003-4318-0382
Michael HolsgroveBioElectronics Unit, College of Medical, Veterinary and Life Sciences, University of Glasgow, Glasgow, G12 8QQ, UK.
Jakup CzyzewskiBioElectronics Unit, College of Medical, Veterinary and Life Sciences, University of Glasgow, Glasgow, G12 8QQ, UK.
Nosrat MirzaiBioElectronics Unit, College of Medical, Veterinary and Life Sciences, University of Glasgow, Glasgow, G12 8QQ, UK.
John R MercerInstitute of Cardiovascular and Medical Sciences/British Heart Foundation, University of Glasgow, Glasgow, G12 8QQ, UK.ORCID 0000-0002-3204-7511
Steve L NealeCentre for Medical and Industrial Ultrasonics, James Watt School of Engineering, University of Glasgow, Glasgow, G12 8QQ, UK.ORCID 0000-0002-4588-276X
University of Glasgow · GBBritish Heart Foundation · GB

Funding

BHF Centre of Research Excellence RE/13/5/30177Engineering and Physical Sciences Research Council EP/R020892/1Engineering and Physical Sciences Research Council EP/S515401/1Medical Research Council MC_PC_19039Veterinary and Life Sciences, Chief Science Office, Scotland Award CGA/17/29
6 · The paper itself

Abstract

Many cardiovascular problems stem from blockages that form within the vasculature and often treatment includes fitting a stent through percutaneous coronary intervention. This offers a minimally invasive therapy but re-occlusion through restenosis or thrombosis formation often occurs post-deployment. Research is ongoing into the creation of smart stents that can detect the occurrence of further problems. In this study, it is shown that selectively metalizing a non-conductive stent can create a set of electrodes that are capable of detecting a build-up of material around the stent. The associated increase in electrical impedance across the electrodes is measured, testing the stent with blood clot to mimic thrombosis. It is shown that the device is capable of sensing different amounts of occlusion. The stent can reproducibly sense the presence of clot showing a 16% +/-3% increase in impedance which is sufficient to reliably detect the clot when surrounded by explanted aorta (one sample t-test, p = 0.009, n = 9). It is demonstrated that this approach can be extended beyond the 3D printed prototypes by showing that it can be applied to a commercially available stent and it is believed that it can be further utilized by other types of medical implants.

Indexed as

Biosensing TechniquesStentsThrombosisAnimalsElectric ImpedanceHumans3D printingblood clotcardiovascular diseaseimpedance sensorrestenosissmart Stent

Identifiers

PMID38342628
PMCPMC11151072
OpenAlexW4392730234

What OpenQuestion holds

Textmetadata
LicenceCC BY