Evidence map›Paper›PMID 38339627›Full record

ArticleSensors (Basel, Switzerland)2024

Characterisation of a Silicon Photomultiplier Based Oncological Brachytherapy Fibre Dosimeter.

Massimo Caccia, Agnese Giaz, Marco Galoppo, Romualdo Santoro, Micheal Martyn, Carla Bianchi, Raffaele Novario, Peter Woulfe, Sinead O'Keeffe

Open access · goldAbstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
4.3field-weighted citation impact, top 6% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 7 citations in OpenAlex.

  1. Article
  2. Understanding the Nonlinear Response of SiPMs.Sensors (Basel, Switzerland) · 2024
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 3 institutions in 2 countries.

Massimo CacciaDipartimento di Scienza e Alta Tecnologia, Università degli Studi dell'Insubria, via Valleggio 11, 22100 Como, Italy.
Agnese GiazDipartimento di Scienza e Alta Tecnologia, Università degli Studi dell'Insubria, via Valleggio 11, 22100 Como, Italy.
Marco GaloppoDipartimento di Scienza e Alta Tecnologia, Università degli Studi dell'Insubria, via Valleggio 11, 22100 Como, Italy.
Romualdo SantoroDipartimento di Scienza e Alta Tecnologia, Università degli Studi dell'Insubria, via Valleggio 11, 22100 Como, Italy.ORCID 0000-0002-4360-4600
Micheal MartynRadiotherapy Department, Galway Clinic, Doughiska Road, H91 HHT0 Galway, Ireland.ORCID 0000-0002-9730-1402
Carla BianchiOspedale di Circolo di Varese, Università degli Studi dell'Insubria, Viale Borri, 57, 21100 Varese, Italy.
Raffaele NovarioOspedale di Circolo di Varese, Università degli Studi dell'Insubria, Viale Borri, 57, 21100 Varese, Italy.
Peter WoulfeOspedale di Circolo di Varese, Università degli Studi dell'Insubria, Viale Borri, 57, 21100 Varese, Italy.
Sinead O'KeeffeOptical Fibre Sensors Research Centre, University of Limerick, V94 T9PX Limerick, Ireland.
University of Insubria · ITGalway Clinic · IEUniversity of Limerick · IE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Source localisation and real-time dose verification are at the forefront of medical research in brachytherapy, an oncological radiotherapy procedure based on radioactive sources implanted in the patient body. The ORIGIN project aims to respond to this medical community's need by targeting the development of a multi-point dose mapping system based on fibre sensors integrating a small volume of scintillating material into the tip and interfaced with silicon photomultipliers operated in counting mode. In this paper, a novel method for the selection of the optimal silicon photomultipliers to be used is presented, as well as a laboratory characterisation based on dosimetric figures of merit. More specifically, a technique exploiting the optical cross-talk to maintain the detector linearity in high-rate conditions is demonstrated. Lastly, it is shown that the ORIGIN system complies with the TG43-U1 protocol in high and low dose rate pre-clinical trials with actual brachytherapy sources, an essential requirement for assessing the proposed system as a dosimeter and comparing the performance of the system prototype against the ORIGIN project specifications.

Indexed as

BrachytherapyHumansRadiation DosimetersRadiometryRadiotherapy DosageSoftwarebrachytherapydosimetryHDRLDRSiPM

Identifiers

PMID38339627
PMCPMC10856931
OpenAlexW4391344364

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked