ArticleSensors (Basel, Switzerland)2024
Efficient and Accurate Analog Voltage Measurement Using a Direct Sensor-to-Digital Port Interface for Microcontrollers and Field-Programmable Gate Arrays.
Article in Sensors (Basel, Switzerland), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
1 author.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Portable sensor systems are usually based on microcontrollers and/or Field-Programmable Gate Arrays (FPGAs) that are interfaced with sensors by means of an Analog-to-Digital converter (ADC), either integrated in the computing device or external. An alternative solution is based on the direct connection of the sensors to the digital input port of the microcontroller or FPGA. This solution is particularly interesting in the case of devices not integrating an internal ADC or featuring a small number of ADC channels. In this paper, a technique is presented to directly interface sensors with analog voltage output to the digital input port of a microcontroller or FPGA. The proposed method requires only a few passive components and is based on the measurements of the duty cycle of a digital square-wave signal. This technique was investigated by means of circuit simulations using LTSpice and was implemented in a commercial low-cost FPGA device (Gowin GW1NR-9). The duty cycle of the square-wave signal features a good linear correlation with the analog voltage to be measured. Thus, a look-up table to map the analog voltage values to the measured duty cycle is not required with benefits in terms of memory occupation. The experimental results on the FPGA device have shown that the analog voltage can be measured with a maximum accuracy of 1.09 mV and a sampling rate of 9.75 Hz. The sampling rate can be increased to 31.35 Hz and 128.31 Hz with an accuracy of 1.61 mV and 2.68 mV, respectively.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.