Evidence map›Paper›PMID 38339578›Full record

ArticleSensors (Basel, Switzerland)2024

Implantable pH Sensing System Using Vertically Stacked Silicon Nanowire Arrays and Body Channel Communication for Gastroesophageal Reflux Monitoring.

Changhee Kim, Seungju Han, Taehwan Kim, Sangmin Lee

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Changhee KimDepartment of Electronics and Information Convergence Engineering, Kyunghee University, Yongin 17104, Republic of Korea.
Seungju HanDepartment of Electronics and Information Convergence Engineering, Kyunghee University, Yongin 17104, Republic of Korea.
Taehwan KimDepartment of Electronics and Information Convergence Engineering, Kyunghee University, Yongin 17104, Republic of Korea.
Sangmin LeeDepartment of Biomedical Engineering, Kyunghee University, Yongin 17104, Republic of Korea.ORCID 0000-0002-4396-6118

Funding

National Research Foundation of Korea 2021R1F1A1049758
6 · The paper itself

Abstract

Silicon nanowires (SiNWs) are emerging as versatile components in the fabrication of sensors for implantable medical devices because of their exceptional electrical, optical, and mechanical properties. This paper presents a novel top-down fabrication method for vertically stacked SiNWs, eliminating the need for wet oxidation, wet etching, and nanolithography. The integration of these SiNWs into body channel communication (BCC) circuits was also explored. The fabricated SiNWs were confirmed to be capable of forming arrays with multiple layers and rows. The SiNW-based pH sensors demonstrated a robust response to pH changes, and when tested with BCC circuits, they showed that it was possible to quantize based on pH when transmitting data through the human body. This study successfully developed a novel method for SiNW fabrication and integration into BCC circuits, which could lead to improvements in the reliability and efficiency of implantable medical sensors. The findings demonstrate significant potential for bioelectronic applications and real-time biochemical monitoring.

Indexed as

Gastroesophageal RefluxNanowiresCommunicationHumansHydrogen-Ion ConcentrationProstheses and ImplantsReproducibility of ResultsSiliconSiliconbody channel communicationMEMSpH sensorsilicon nanowire

Identifiers

PMID38339578
PMCPMC10857522

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.