Evidence map›Paper›PMID 38339491›Full record

ArticleSensors (Basel, Switzerland)2024

Segmentation of Low-Light Optical Coherence Tomography Angiography Images under the Constraints of Vascular Network Topology.

Zhi Li, Gaopeng Huang, Binfeng Zou, Wenhao Chen, Tianyun Zhang, Zhaoyang Xu, Kunyan Cai, Tingyu Wang, Yaoqi Sun, Yaqi Wang and 2 more

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

12 authors.

Zhi LiSchool of Automation, Hangzhou Dianzi University, Hangzhou 310018, China.ORCID 0000-0002-8789-0151
Gaopeng HuangSchool of Automation, Hangzhou Dianzi University, Hangzhou 310018, China.ORCID 0009-0008-3190-5669
Binfeng ZouSchool of Automation, Hangzhou Dianzi University, Hangzhou 310018, China.
Wenhao ChenSchool of Automation, Hangzhou Dianzi University, Hangzhou 310018, China.
Tianyun ZhangSchool of Automation, Hangzhou Dianzi University, Hangzhou 310018, China.
Zhaoyang XuDepartment of Paediatrics, University of Cambridge, Cambridge CB2 1TN, UK.
Kunyan CaiFaculty of Applied Sciences, Macao Polytechnic University, Macao SAR 999078, China.ORCID 0009-0006-9186-418X
Tingyu WangSchool of Automation, Hangzhou Dianzi University, Hangzhou 310018, China.
Yaoqi SunSchool of Automation, Hangzhou Dianzi University, Hangzhou 310018, China.
Yaqi WangCollege of Media Engineering, Communication University of Zhejiang, Hangzhou 310018, China.ORCID 0000-0002-4627-3392
Kai JinEye Center, The Second Affiliated Hospital, School of Medicine, Zhejiang University, Hangzhou 310027, China.ORCID 0000-0003-4369-2417
Xingru HuangSchool of Automation, Hangzhou Dianzi University, Hangzhou 310018, China.ORCID 0000-0003-3971-8434

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Optical coherence tomography angiography (OCTA) offers critical insights into the retinal vascular system, yet its full potential is hindered by challenges in precise image segmentation. Current methodologies struggle with imaging artifacts and clarity issues, particularly under low-light conditions and when using various high-speed CMOS sensors. These challenges are particularly pronounced when diagnosing and classifying diseases such as branch vein occlusion (BVO). To address these issues, we have developed a novel network based on topological structure generation, which transitions from superficial to deep retinal layers to enhance OCTA segmentation accuracy. Our approach not only demonstrates improved performance through qualitative visual comparisons and quantitative metric analyses but also effectively mitigates artifacts caused by low-light OCTA, resulting in reduced noise and enhanced clarity of the images. Furthermore, our system introduces a structured methodology for classifying BVO diseases, bridging a critical gap in this field. The primary aim of these advancements is to elevate the quality of OCTA images and bolster the reliability of their segmentation. Initial evaluations suggest that our method holds promise for establishing robust, fine-grained standards in OCTA vascular segmentation and analysis.

Indexed as

Retinal Vein OcclusionTomography, Optical CoherenceAngiographyHumansReproducibility of ResultsRetinal Vesselsmedical image processingoptical coherence tomography angiographyretinal vein occlusionretinal vessel segmentation

Identifiers

PMID38339491
PMCPMC10856982

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.