Evidence map›Paper›PMID 38339446›Full record

ArticleSensors (Basel, Switzerland)2024

Optrode-Assisted Multiparametric Near-Infrared Spectroscopy for the Analysis of Liquids.

Maria Giulia Delli Santi, Salvatore Castrignano, Marialuisa Capezzuto, Marco Consales, Patrizio Vaiano, Andrea Cusano, Gianluca Gagliardi, Pietro Malara

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Maria Giulia Delli SantiConsiglio Nazionale delle Ricerche, Istituto Nazionale di Ottica (CNR-INO), Via Campi Flegrei 34, 80078 Pozzuoli, Italy.
Salvatore CastrignanoConsiglio Nazionale delle Ricerche, Istituto Nazionale di Ottica (CNR-INO), Via Campi Flegrei 34, 80078 Pozzuoli, Italy.ORCID 0009-0003-2894-111X
Marialuisa CapezzutoConsiglio Nazionale delle Ricerche, Istituto Nazionale di Ottica (CNR-INO), Via Campi Flegrei 34, 80078 Pozzuoli, Italy.
Marco ConsalesOptoelectronics Group, Engineering Department, University of Sannio, C.so Garibaldi 107, 82100 Benevento, Italy.ORCID 0000-0002-6208-3687
Patrizio VaianoOptoelectronics Group, Engineering Department, University of Sannio, C.so Garibaldi 107, 82100 Benevento, Italy.ORCID 0000-0002-7874-3352
Andrea CusanoOptoelectronics Group, Engineering Department, University of Sannio, C.so Garibaldi 107, 82100 Benevento, Italy.
Gianluca GagliardiConsiglio Nazionale delle Ricerche, Istituto Nazionale di Ottica (CNR-INO), Via Campi Flegrei 34, 80078 Pozzuoli, Italy.ORCID 0000-0003-0638-428X
Pietro MalaraConsiglio Nazionale delle Ricerche, Istituto Nazionale di Ottica (CNR-INO), Via Campi Flegrei 34, 80078 Pozzuoli, Italy.

Funding

Italian Ministry of University and Research 20173CRP3H_003
6 · The paper itself

Abstract

We demonstrate a sensing scheme for liquid analytes that integrates multiple optical fiber sensors in a near-infrared spectrometer. With a simple optofluidic method, a broadband radiation is encoded in a time-domain interferogram and distributed to different sensing units that interrogate the sample simultaneously; the spectral readout of each unit is extracted from its output signal by a Fourier transform routine. The proposed method allows performing a multiparametric analysis of liquid samples in a compact setup where the radiation source, measurement units, and spectral readout are all integrated in a robust telecom optical fiber. An experimental validation is provided by combining a plasmonic nanostructured fiber probe and a transmission cuvette in the setup and demonstrating the simultaneous measurement of the absorption spectrum and the refractive index of water-methanol solutions.

Indexed as

fiber optics sensorslab-on-fiber sensorsmultiparametric analysisNIR spectroscopyportable spectrometers

Identifiers

PMID38339446
PMCPMC10857342

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked