Evidence map›Paper›PMID 38337431›Full record

ArticleJournal of clinical medicine2024

Comparison of Patient-Specific Condylar Positioning Devices and Manual Methods in Orthognathic Surgery: A Prospective Randomized Trial.

Anton Straub, Sebastian Gubik, Alexander Kübler, Niko Breitenbuecher, Andreas Vollmer, Tobias Renner, Urs Müller-Richter, Stefan Hartmann, Roman Brands

Open access · goldAbstract read
In one paragraph

Article in Journal of clinical medicine, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
1.5field-weighted citation impact, top 21% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 3 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 1 institution in 1 country.

Anton StraubDepartment of Oral and Maxillofacial Plastic Surgery, University Hospital Würzburg, Pleicherwall 2, 97070 Würzburg, Germany.ORCID 0000-0002-9452-9380
Sebastian GubikDepartment of Oral and Maxillofacial Plastic Surgery, University Hospital Würzburg, Pleicherwall 2, 97070 Würzburg, Germany.ORCID 0009-0006-7312-5519
Alexander KüblerDepartment of Oral and Maxillofacial Plastic Surgery, University Hospital Würzburg, Pleicherwall 2, 97070 Würzburg, Germany.
Niko BreitenbuecherDepartment of Oral and Maxillofacial Plastic Surgery, University Hospital Würzburg, Pleicherwall 2, 97070 Würzburg, Germany.
Andreas VollmerDepartment of Oral and Maxillofacial Plastic Surgery, University Hospital Würzburg, Pleicherwall 2, 97070 Würzburg, Germany.ORCID 0000-0002-2697-5143
Tobias RennerDepartment of Oral and Maxillofacial Plastic Surgery, University Hospital Würzburg, Pleicherwall 2, 97070 Würzburg, Germany.
Urs Müller-RichterDepartment of Oral and Maxillofacial Plastic Surgery, University Hospital Würzburg, Pleicherwall 2, 97070 Würzburg, Germany.ORCID 0000-0001-7869-7686
Stefan HartmannDepartment of Oral and Maxillofacial Plastic Surgery, University Hospital Würzburg, Pleicherwall 2, 97070 Würzburg, Germany.
Roman BrandsDepartment of Oral and Maxillofacial Plastic Surgery, University Hospital Würzburg, Pleicherwall 2, 97070 Würzburg, Germany.
Universitätsklinikum Würzburg · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThis study investigated whether patient-specific condylar positioning devices (CPDs) are beneficial compared to the conventional manual positioning of the condyles.

methodsIn this prospective, randomized trial, patients undergoing orthognathic surgery with a bilateral sagittal split osteotomy of the mandible were included. The ascending ramus was positioned with computer-aided designed and computer-aided manufactured (CAD/CAM) patient-specific devices in the CPD group and manually in the control group. Postoperatively, cone-beam computed tomography (CBCT) was performed to align the virtually planned position with the postoperative result.

resultsThirty patients were enrolled in the study, with 14 randomized to the CPD group and 16 to the control group. In the CPD group, the ascending ramus differed in the postoperative CBCT scan from the virtually planned position by 0.8 mm in the left/right, 0.8 mm in the front/back, and 1.3 mm in the cranial/caudal direction. The corresponding control-group values were 1.1 mm, 1.3 mm, and 1.6 mm. CPD and controls differed significantly for the left/right movement of the rami (

conclusionsThe results demonstrate that both methods are accurate, and postoperative results matched the virtually planned position precisely. It can be assumed that the described CPDs are beneficial when a condylar position different from the preoperative is desired.

Indexed as

ascending ramusbilateral sagittal split osteotomyCAD/CAMcondylar positioning devicetemporomandibular jointvirtually planned position

Identifiers

PMID38337431
PMCPMC10856595
OpenAlexW4391363016

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.