Evidence map›Paper›PMID 38336983›Full record

ArticleScientific reports2024

Comparative study on measurements of radiochromic films using portable colorimeters.

Hiroshi Yasuda, Shido Morioka

Abstract read
In one paragraph

Article in Scientific reports, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Review
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors.

Hiroshi YasudaResearch Institute for Radiation Biology and Medicine (RIRBM), Hiroshima University, Kasumi 1-2-3, Minami-ku, Hiroshima, 734-8553, Japan. hyasuda@hiroshima-u.ac.jp.
Shido MoriokaSchool of Medicine, Hiroshima University, Kasumi 1-2-3 Minami-ku, Hiroshima, 734-8553, Japan.

Funding

Japan Society for the Promotion of Science 18KK0417
6 · The paper itself

Abstract

The recently proposed method for on-site radiation dosimetry by a combination of radiochromic film and portable colorimeter was tested for six combinations of two popular Gafchromic films (EBT3 and EBT-XD) and three commercially available portable colorimeters (nix pro2, nix spectro2 and Spectro1 Pro; abbreviated to "NixP", "NixS" and "SpoP", respectively). EBT3 and EBT-XD were irradiated with X-rays (160 kV, 6.3 mA) up to 40 Gy and 80 Gy, respectively, and the radiation-induced color levels of RGB and CMYK components were measured with the three colorimeters. Angle dependence was examined by reading at 15° intervals. As a result, it was judged that all combinations would work effectively under certain irradiation conditions. NixP and NixS were applicable to a wider dose range for both films, while SpoP fit a lower dose range. On the other hand, SpoP showed an advantageous feature of no angular dependence in reading films, while NixP and NixS showed significant angle-dependent changes. These differences are considered to be attributable to the different geometries of LED light emission, which came from all directions (360°) in SpoP, 4 directions in NixP, and 8 directions in NixS. These findings are expected to expand the applicability of the novel method to various occasions of on-site dosimetry.

Identifiers

PMID38336983
PMCPMC10858274

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.