Evidence map›Paper›PMID 38336781›Full record

ArticleBiomedical engineering online2024

Deep neural networks for wearable sensor-based activity recognition in Parkinson's disease: investigating generalizability and model complexity.

Shelly Davidashvilly, Maria Cardei, Murtadha Hssayeni, Christopher Chi, Behnaz Ghoraani

Open access · goldAbstract read
In one paragraph

Article in Biomedical engineering online, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
17.2field-weighted citation impact, top 1% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 10 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 2 countries.

Shelly DavidashvillyElectrical and Computer Engineering, Florida Atlantic University, Boca Raton, FL, 33431, US.
Maria CardeiElectrical and Computer Engineering, Florida Atlantic University, Boca Raton, FL, 33431, US.
Murtadha HssayeniElectrical and Computer Engineering, Florida Atlantic University, Boca Raton, FL, 33431, US.
Christopher ChiElectrical and Computer Engineering, Florida Atlantic University, Boca Raton, FL, 33431, US.
Behnaz GhoraaniElectrical and Computer Engineering, Florida Atlantic University, Boca Raton, FL, 33431, US. bghoraani@fau.edu.
Florida Atlantic University · USUniversity of Technology - Iraq · IQ

Funding

Kinesia-D: Ambulatory PD Dyskinesia Monitor for Drug Therapy TitrationR44AG044293 · NIA · GREAT LAKES NEUROTECHNOLOGIES · PI PULLIAM, CHRISTOPHER LEE · 2013 to 2014
$1.7M
Kinesia-D: Ambulatory Parkinson's Disease Dyskinesia Monitor for Drug Therapy TitR43NS071882 · NINDS · GREAT LAKES NEUROTECHNOLOGIES · PI MERA, THOMAS OLIVER · 2011 to 2011
$237k
National Science Foundation 1936586National Science Foundation 1950400NIA NIH HHS R44 AG044293NINDS NIH HHS R43 NS071882
6 · The paper itself

Abstract

backgroundThe research gap addressed in this study is the applicability of deep neural network (NN) models on wearable sensor data to recognize different activities performed by patients with Parkinson's Disease (PwPD) and the generalizability of these models to PwPD using labeled healthy data.

methodsThe experiments were carried out utilizing three datasets containing wearable motion sensor readings on common activities of daily living. The collected readings were from two accelerometer sensors. PAMAP2 and MHEALTH are publicly available datasets collected from 10 and 9 healthy, young subjects, respectively. A private dataset of a similar nature collected from 14 PwPD patients was utilized as well. Deep NN models were implemented with varying levels of complexity to investigate the impact of data augmentation, manual axis reorientation, model complexity, and domain adaptation on activity recognition performance.

resultsA moderately complex model trained on the augmented PAMAP2 dataset and adapted to the Parkinson domain using domain adaptation achieved the best activity recognition performance with an accuracy of 73.02%, which was significantly higher than the accuracy of 63% reported in previous studies. The model's F1 score of 49.79% significantly improved compared to the best cross-testing of 33.66% F1 score with only data augmentation and 2.88% F1 score without data augmentation or domain adaptation.

conclusionThese findings suggest that deep NN models originating on healthy data have the potential to recognize activities performed by PwPD accurately and that data augmentation and domain adaptation can improve the generalizability of models in the healthy-to-PwPD transfer scenario. The simple/moderately complex architectures tested in this study could generalize better to the PwPD domain when trained on a healthy dataset compared to the most complex architectures used. The findings of this study could contribute to the development of accurate wearable-based activity monitoring solutions for PwPD, improving clinical decision-making and patient outcomes based on patient activity levels.

Indexed as

Parkinson DiseaseWearable Electronic DevicesActivities of Daily LivingHumansMotionNeural Networks, ComputerData augmentationDeep neural networksDomain adaptationGeneralizabilityHuman activity recognitionParkinson’s diseaseWearable sensors

Identifiers

PMID38336781
PMCPMC10858599
OpenAlexW4391692728

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.