Evidence map›Paper›PMID 38335798›Full record

ArticleNeuropeptides2024

Measurement of neuropeptide Y with molecularly imprinted polypyrrole on carbon fiber microelectrodes.

Luis López, Kelly Lozano, John Cruz, Krystal Flores, Lauren Fernández-Vega, Lisandro Cunci

Open access · greenAbstract read
In one paragraph

Article in Neuropeptides, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
2.4field-weighted citation impact, top 14% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 7 citations in OpenAlex.

  1. Article
  2. Neuropeptide Y and Pain: Insights from Brain Research.ACS pharmacology & translational science · 2024
    Review
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 1 country.

Luis LópezDepartment of Chemistry, University of Puerto Rico - Rio Piedras, 17 Ave Universidad Ste 1701, San Juan, PR 00931, United States.
Kelly LozanoDepartment of Chemistry, Universidad Ana G. Méndez, Carr. 189, Km 3.3, Gurabo, PR 00778, United States.
John CruzDepartment of Chemistry, University of Puerto Rico - Rio Piedras, 17 Ave Universidad Ste 1701, San Juan, PR 00931, United States.
Krystal FloresDepartment of Chemistry, Universidad Ana G. Méndez, Carr. 189, Km 3.3, Gurabo, PR 00778, United States.
Lauren Fernández-VegaDepartment of Chemistry, Universidad Ana G. Méndez, Carr. 189, Km 3.3, Gurabo, PR 00778, United States.
Lisandro CunciDepartment of Chemistry, University of Puerto Rico - Rio Piedras, 17 Ave Universidad Ste 1701, San Juan, PR 00931, United States. Electronic address: lisandro.cunci@upr.edu.
Ana G. Mendez University System · PRUniversity of Puerto Rico at Río Piedras · PR

Funding

SCIENCE AND TECHNOLOGY COMPETENCY & EDUCATION CORE (STCE)P20GM103475 · NIGMS · UNIVERSITY OF PUERTO RICO MED SCIENCES · PI Jose R. Rodriguez-Medina · 2012 to 2026
$52.9M
Development and Validation of an NPY-sensitive Microelectrode for Measuring NPY Release from HippocampusR21MH129037 · NIMH · UNIVERSITY COLLEGE OF TURABO (CAGUAS,PR) · PI CUNCI, LISANDRO, DOBRUNZ, LYNN E · 2021 to 2022
$382k
NIGMS NIH HHS P20 GM103475NIMH NIH HHS R21 MH129037
6 · The paper itself

Abstract

The measurement of neuropeptides using small electrodes for high spatial resolution would provide us with localized information on the release of neuromolecules. The release of Neuropeptide Y (NPY) is related to different neurological diseases such as stress, obesity, and PTSD, among others. In this conference paper, we electrodeposited polypyrrole on carbon fiber microelectrodes in the presence of NPY to develop a molecularly imprinted polypyrrole sensitive to NPY. Optimization of the electrodeposition process resulted in the full coverage of the polymer with nucleation sites on the carbon fiber ridges, achieving completion by the seventh cycle. Electrodeposition was performed for five cycles, and using cyclic voltammetry (CV), we studied the change in the oxidation current peak for polypyrrole due to the presence of NPY. We also observed a change in capacitance due to the presence of NPY, which was studied by electrochemical impedance spectroscopy (EIS). A linear correlation was found between the oxidation peak and the concentration of NPY between 50 ng/mL and 1000 ng/mL. In addition, a linear correlation was also found between microelectrode capacitance and the concentration of NPY between 50 ng/mL and 1000 ng/mL at 100 kHz.

Indexed as

Neuropeptide YPolymersCarbon FiberMicroelectrodesPyrrolesCarbon FiberNeuropeptide YPolymerspolypyrrolePyrrolesBiosensorCarbon fiber microelectrodeMolecular imprintingNeuropeptide Y

Identifiers

PMID38335798
PMCPMC10940184
OpenAlexW4391529785

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.