Evidence map›Paper›PMID 38333399›Full record

ArticleJournal of arrhythmia2024

The effect of ablation settings on lesion characteristics with DiamondTemp ablation system: An ex vivo experiment.

Takehiro Nomura, Manabu Maeda, Daiki Kumazawa, Yosuke Mizuno, Kosuke Onodera, Shigeru Toyoda, Kennosuke Yamashita

Open access · goldAbstract read
In one paragraph

Article in Journal of arrhythmia, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
1.3field-weighted citation impact, top 17% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 6 citations in OpenAlex.

  1. Article
  2. Bipolar radiofrequency ablation of refractory ventricular arrhythmias: results from a multicentre network.Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2024
    Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 2 institutions in 1 country.

Takehiro NomuraHeart Rhythm Center, Department of Cardiovascular Medicine Sendai Kosei Hospital Sendai-shi Miyagi Japan.ORCID https://orcid.org/0000-0003-4826-2184
Manabu MaedaHeart Rhythm Center, Department of Cardiovascular Medicine Sendai Kosei Hospital Sendai-shi Miyagi Japan.
Daiki KumazawaHeart Rhythm Center, Department of Cardiovascular Medicine Sendai Kosei Hospital Sendai-shi Miyagi Japan.
Yosuke MizunoHeart Rhythm Center, Department of Cardiovascular Medicine Sendai Kosei Hospital Sendai-shi Miyagi Japan.
Kosuke OnoderaHeart Rhythm Center, Department of Cardiovascular Medicine Sendai Kosei Hospital Sendai-shi Miyagi Japan.
Shigeru ToyodaDepartment of Cardiovascular Medicine, School of Medicine Dokkyo Medical University Mibu Tochigi Japan.
Kennosuke YamashitaHeart Rhythm Center, Department of Cardiovascular Medicine Sendai Kosei Hospital Sendai-shi Miyagi Japan.
Sendai Shakai Hoken Hospital · JPDokkyo Medical University · JP

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Introduction: Creating large lesion in ablations using the DiamondTemp (DTA) ablation system may reduce the frequency of arrhythmia recurrence and allow the treatment of ventricular arrhythmias. Therefore, this study aimed to investigate whether power, application time, contact force (CF), and contact angle affect lesion formation in the ventricles. Methods: Ablations were delivered to porcine myocardial preps to evaluate the lesion characteristics. Ablations were conducted with a maximum power of 50 W, target temperature of 58°C, CF of 10, 20, or 30 g, and contact angle between the catheter tip and tissue. The ablation durations were 15, 30, 60 s, 15 s × 2, or 30 s × 2. Results: Steam pops occurred only in cases with perpendicular contact. The lesion depth was larger in all settings in the perpendicular orientation than in the parallel orientation. The temperatures were lower in all settings in the perpendicular orientation than in the parallel orientation. The lesions became larger as CF increased with perpendicular contact and duration of ≥30 s. The longer application time resulted in larger surface area, depth, and volume of the lesion. Lesion depth was greater with single application of 30 and 60 s than with 15 s × 2 and 30 s × 2, respectively. Conclusion: It is important to perform a single prolonged application as much as possible to create deeper lesions. Parallel contact with the tissue should be maintained to take advantage of the temperature sensor's capabilities to avoid pop phenomenon.

Indexed as

catheter ablationdiamond tipexperimental modelnew technologytemperature control

Identifiers

PMID38333399
PMCPMC10848608
OpenAlexW4389410163

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.