Evidence map›Paper›PMID 38332177›Full record

ArticleScientific reports2024

Breast cancer detection using enhanced IRI-numerical engine and inverse heat transfer modeling: model description and clinical validation.

Carlos Gutierrez, Alyssa Owens, Lori Medeiros, Donnette Dabydeen, Nithya Sritharan, Pradyumna Phatak, Satish G Kandlikar

Open access · goldAbstract read
In one paragraph

Article in Scientific reports, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
5.3field-weighted citation impact, top 4% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 13 citations in OpenAlex.

  1. Studying the Effects of Large Vessel Myocardial Perfusion in a Tissue-emulating Cardiac Phantom: In vitro and in silico findings.Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference · 2025
    Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 2 institutions in 1 country.

Carlos GutierrezRochester Institute of Technology, Rochester, USA.
Alyssa OwensRochester Institute of Technology, Rochester, USA.
Lori MedeirosRochester Regional Health, Rochester, USA.
Donnette DabydeenRochester Regional Health, Rochester, USA.
Nithya SritharanRochester Regional Health, Rochester, USA.
Pradyumna PhatakRochester Regional Health, Rochester, USA.
Satish G KandlikarRochester Institute of Technology, Rochester, USA. sgkeme@rit.edu.
Unity Health System · USRochester Institute of Technology · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Effective treatment of breast cancer relies heavily on early detection. Routine annual mammography is a widely accepted screening technique that has resulted in significantly improving the survival rate. However, it suffers from low sensitivity resulting in high false positives from screening. To overcome this problem, adjunctive technologies such as ultrasound are employed on about 10% of women recalled for additional screening following mammography. These adjunctive techniques still result in a significant number of women, about 1.6%, who undergo biopsy while only 0.4% of women screened have cancers. The main reason for missing cancers during mammography screening arises from the masking effect of dense breast tissue. The presence of a tumor results in the alteration of temperature field in the breast, which is not influenced by the tissue density. In the present paper, the IRI-Numerical Engine is presented as an adjunct for detecting cancer from the surface temperature data. It uses a computerized inverse heat transfer approach based on Pennes's bioheat transfer equations. Validation of this enhanced algorithm is conducted on twenty-three biopsy-proven breast cancer patients after obtaining informed consent under IRB protocol. The algorithm correctly predicted the size and location of cancerous tumors in twenty-four breasts, while twenty-two contralateral breasts were also correctly predicted to have no cancer (one woman had bilateral breast cancer). The tumors are seen as highly perfused and metabolically active heat sources that alter the surface temperatures that are used in heat transfer modeling. Furthermore, the results from this study with twenty-four biopsy-proven cancer cases indicate that the detection of breast cancer is not affected by breast density. This study indicates the potential of the IRI-Numerical Engine as an effective adjunct to mammography. A large scale clinical study in a statistically significant sample size is needed before integrating this approach in the current protocol.

Indexed as

Breast NeoplasmsBreastBreast DensityEarly Detection of CancerFemaleHot TemperatureHumansMammography

Identifiers

PMID38332177
PMCPMC10853496
OpenAlexW4391687127

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.