Evidence map›Paper›PMID 38332136›Full record

ArticleScientific reports2024

Benchmarking signal quality and spatiotemporal distribution of interictal spikes in prolonged human iEEG recordings using CorTec wireless brain interchange.

Amir Hossein Ayyoubi, Behrang Fazli Besheli, Michael M Quach, Jay R Gavvala, Alica M Goldman, Chandra Prakash Swamy, Eleonora Bartoli, Daniel J Curry, Sameer A Sheth, David J Francis and 1 more

2 registry-linked trialsOpen access · goldAbstract read
In one paragraph

Article in Scientific reports, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to 2 registered trials, which are not on this map. Cited by 10 papers.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed
3.1field-weighted citation impact, top 9% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT05439655 naactive not recruitingnot on this map

Acute Recording of Stereotyped High-Frequency Oscillations With a Closed-Loop Brain Interchange System in Drug-Resistant Epilepsy

TypeinterventionalSponsorMayo ClinicRan2021 to 2026Enrolled12ConditionsEpilepsyArmsBrain Interchange System
NCT06898138 nanot yet recruitingnot on this mapstarted 2026, after this paper: background citation

Acute Stimulation for the Modulation of Epileptic Events With a Closed-Loop Brain Interchange System in Drug Resistant Epilepsy

TypeinterventionalSponsorMayo ClinicRan2026 to 2029Enrolled8ConditionsEpilepsyArmsBrain Interchange System
3 · Its place in the literature

Who cites it

10 citing papers in PubMed, 9 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. A RAPID PROTOTYPING ENVIRONMENT FOR CLOSED-LOOP NEUROMODULATION USING THE BRAIN INTERCHANGE SYSTEM.Proceedings of the ... Design of Medical Devices Conference. Design of Medical Devices Conference · 2026
    Article
  5. Review
  6. AN ONLINE SPIKE DETECTION AND MONITORING FRAMEWORK IN IEEG RECORDED USING BRAIN INTERCHANGE DEVICE.Proceedings of the ... International Brain-Computer Interface Conference · 2024
    Article
  7. A Synchronous iEEG Data Acquisition Framework for Dual Brain Interchange Systems.The ... Midwest Symposium on Circuits and Systems conference proceedings : MWSCAS. Midwest Symposium on Circuits and Systems · 2024
    Article
  8. Mitigating Effects of Packet Loss in Wireless Neural Data Transfer: Exploring the Influence of Low-Cost Recovery Methods on Spikes and HFOs in iEEG.The ... Midwest Symposium on Circuits and Systems conference proceedings : MWSCAS. Midwest Symposium on Circuits and Systems · 2024
    Article
  9. A real-time HFO detection framework for localization of SOZ in iEEG recording of patients with epilepsy.Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference · 2024
    Article
  10. Development and Evaluation of a Real-Time Phase-Triggered Stimulation Algorithm for the CorTec Brain Interchange.IEEE transactions on neural systems and rehabilitation engineering : a publication of the IEEE Engineering in Medicine and Biology Society · 2024
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors at 6 institutions in 1 country.

Amir Hossein AyyoubiDepartment of Biomedical Engineering, University of Houston, Houston, TX, USA.
Behrang Fazli BesheliDepartment of Biomedical Engineering, University of Houston, Houston, TX, USA.
Michael M QuachDepartment of Neurology, Texas Children's Hospital, Houston, TX, USA.
Jay R GavvalaDepartment of Neurology, UTHealth, Houston, TX, USA.
Alica M GoldmanDepartment of Neurology, Baylor College of Medicine, Houston, TX, USA.
Chandra Prakash SwamyDepartment of Neurologic Surgery, Mayo Clinic, Rochester, MN, USA.
Eleonora BartoliDepartment of Neurosurgery, Baylor College of Medicine, Houston, TX, USA.
Daniel J CurryDepartment of Neurosurgery, Texas Children's Hospital, Houston, TX, USA.
Sameer A ShethDepartment of Neurosurgery, Baylor College of Medicine, Houston, TX, USA.
David J FrancisDepartment of Psychology, University of Houston, Houston, TX, USA.
Nuri F InceDepartment of Biomedical Engineering, University of Houston, Houston, TX, USA. Ince.Nuri@Mayo.edu.
Baylor College of Medicine · USTexas Children's Hospital · USUniversity of Houston · USWinnMed · USMayo Clinic · USThe University of Texas Health Science Center at Houston · US

Funding

Acute Modulation of Stereotyped High Frequency Oscillations with a Closed-Loop Brain Interchange System in Drug Resistant EpilepsyUH3NS117944 · NINDS · UNIVERSITY OF HOUSTON · PI Nuri Firat Ince · 2021 to 2026
$2.9M
Investigation of Stereotyped High-Frequency Oscillations with Computational Intelligence for the Prediction of Seizure Onset Zone in EpilepsyR01NS112497 · NINDS · UNIVERSITY OF HOUSTON · PI INCE, NURI FIRAT · 2019 to 2023
$2.3M
NIH HHS R01NS112497NIH HHS UH3NS117944NINDS NIH HHS R01 NS112497NINDS NIH HHS UH3 NS117944
6 · The paper itself

Abstract

Neuromodulation through implantable pulse generators (IPGs) represents an important treatment approach for neurological disorders. While the field has observed the success of state-of-the-art interventions, such as deep brain stimulation (DBS) or responsive neurostimulation (RNS), implantable systems face various technical challenges, including the restriction of recording from a limited number of brain sites, power management, and limited external access to the assessed neural data in a continuous fashion. To the best of our knowledge, for the first time in this study, we investigated the feasibility of recording human intracranial EEG (iEEG) using a benchtop version of the Brain Interchange (BIC) unit of CorTec, which is a portable, wireless, and externally powered implant with sensing and stimulation capabilities. We developed a MATLAB/SIMULINK-based rapid prototyping environment and a graphical user interface (GUI) to acquire and visualize the iEEG captured from all 32 channels of the BIC unit. We recorded prolonged iEEG (~ 24 h) from three human subjects with externalized depth leads using the BIC and commercially available clinical amplifiers simultaneously in the epilepsy monitoring unit (EMU). The iEEG signal quality of both streams was compared, and the results demonstrated a comparable power spectral density (PSD) in all the systems in the low-frequency band (< 80 Hz). However, notable differences were primarily observed above 100 Hz, where the clinical amplifiers were associated with lower noise floor (BIC-17 dB vs. clinical amplifiers <  - 25 dB). We employed an established spike detector to assess and compare the spike rates in each iEEG stream. We observed over 90% conformity between the spikes rates and their spatial distribution captured with BIC and clinical systems. Additionally, we quantified the packet loss characteristic in the iEEG signal during the wireless data transfer and conducted a series of simulations to compare the performance of different interpolation methods for recovering the missing packets in signals at different frequency bands. We noted that simple linear interpolation has the potential to recover the signal and reduce the noise floor with modest packet loss levels reaching up to 10%. Overall, our results indicate that while tethered clinical amplifiers exhibited noticeably better noise floor above 80 Hz, epileptic spikes can still be detected successfully in the iEEG recorded with the externally powered wireless BIC unit opening the road for future closed-loop neuromodulation applications with continuous access to brain activity.

Indexed as

ElectrocorticographyEpilepsyBenchmarkingBrainBrain MappingElectroencephalographyHumans

Identifiers

PMID38332136
PMCPMC10853182
OpenAlexW4391646217

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390