Evidence map›Paper›PMID 38329583›Full record

ReviewHeart failure reviews2024

Right ventricular dysfunction in left ventricular assist device candidates: is it time to change our prospective?

Carlotta Sciaccaluga, Maria Cristina Procopio, Luciano Potena, Marco Masetti, Sonia Bernazzali, Massimo Maccherini, Federico Landra, Francesca Maria Righini, Matteo Cameli, Serafina Valente

Open access · hybridAbstract readReview
In one paragraph

Review in Heart failure reviews, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
1.5field-weighted citation impact, top 21% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 8 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Review
  6. Article
  7. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors at 3 institutions in 1 country.

Carlotta Sciaccaluga *Department of Medical Biotechnologies, Division of Cardiology, University of Siena, Siena, Italy. carlotta.sciaccaluga@gmail.com.ORCID 0000-0002-1965-1773
Maria Cristina Procopio *Department of Clinical and Experimental Medicine, University of Messina, Messina, Italy.
Luciano PotenaHeart Failure and Transplant Unit, IRCCS Azienda Ospedaliero-Universitaria di Bologna, Bologna, Italy.
Marco MasettiHeart Failure and Transplant Unit, IRCCS Azienda Ospedaliero-Universitaria di Bologna, Bologna, Italy.
Sonia BernazzaliDepartment of Cardiac Surgery, University of Siena, Siena, Italy.
Massimo MaccheriniDepartment of Cardiac Surgery, University of Siena, Siena, Italy.
Federico LandraDepartment of Medical Biotechnologies, Division of Cardiology, University of Siena, Siena, Italy.
Francesca Maria RighiniDepartment of Medical Biotechnologies, Division of Cardiology, University of Siena, Siena, Italy.
Matteo CameliDepartment of Medical Biotechnologies, Division of Cardiology, University of Siena, Siena, Italy.
Serafina ValenteDepartment of Medical Biotechnologies, Division of Cardiology, University of Siena, Siena, Italy.
University of Siena · ITAzienda USL di Bologna · ITUniversity of Messina · IT

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The use of left ventricular assist devices (LVAD) has significantly increased in the last years, trying to offer a therapeutic alternative to heart transplantation, in light also to the significant heart donor shortage compared to the growing advanced heart failure population. Despite technological improvements in the devices, LVAD-related mortality is still fairly high, with right heart failure being one of the predominant predictors. Therefore, many efforts have been made toward a thorough right ventricular (RV) evaluation prior to LVAD implant, considering clinical, laboratory, echocardiographic, and invasive hemodynamic parameters. However, there is high heterogeneity regarding both which predictor is the strongest as well as the relative cut-off values, and a consensus has not been reached yet, increasing the risk of facing patients in which the distinction between good or poor RV function cannot be surely reached. In parallel, due to technological development and availability of mechanical circulatory support of the RV, LVADs are being considered even in patients with suboptimal RV function. The aim of our review is to analyze the current evidence regarding the role of RV function prior to LVAD and its evaluation, pointing out the extreme variability in parameters that are currently assessed and future prospective regarding new diagnostic tools. Finally, we attempt to gather the available information on the therapeutic strategies to use in the peri-operative phase, in order to reduce the incidence of RV failure, especially in patients in which the preoperative evaluation highlighted some conflicting results with regard to ventricular function.

Indexed as

Heart-Assist DevicesHeart FailureHeart TransplantationVentricular Dysfunction, RightEchocardiographyHumansRetrospective StudiesLVADRight ventricular dysfunctionRight ventricular failure

Identifiers

PMID38329583
PMCPMC10942886
OpenAlexW4391655622

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.