Evidence map›Paper›PMID 38328596›Full record

ArticleJournal of mechanisms and robotics2023

Separable Tendon-Driven Robotic Manipulator with a Long, Flexible, Passive Proximal Section.

Christian DeBuys, Florin C Ghesu, Jagadeesan Jayender, Reza Langari, Young-Ho Kim

Abstract read
In one paragraph

Article in Journal of mechanisms and robotics, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Christian DeBuysTexas A&M University, Mechanical Engineering, College Station, TX, USA.
Florin C GhesuSiemens Healthineersm, Digital Technology & Innovation, Princeton, NJ, USA.
Jagadeesan JayenderSurgical Planning Laboratory, Brigham and Women's Hospital, Harvard Medical School, Boston, USA.
Reza LangariTexas A&M University, Mechanical Engineering, College Station, TX, USA.
Young-Ho KimSiemens Healthineers, Digital Technology & Innovation, Princeton, NJ, USA.

Funding

Robot-Assisted 3D ICE Catheter for Cardiac AblationR01EB028278 · NIBIB · BRIGHAM AND WOMEN'S HOSPITAL · PI JAGADEESAN, JAYENDER · 2020 to 2024
$2.0M
NIBIB NIH HHS R01 EB028278
6 · The paper itself

Abstract

This work tackles practical issues which arise when using a tendon-driven robotic manipulator (TDRM) with a long, flexible, passive proximal section in medical applications. Tendon-driven devices are preferred in medicine for their improved outcomes via minimally invasive procedures, but TDRMs come with unique challenges such as sterilization and reuse, simultaneous control of tendons, hysteresis in the tendon-sheath mechanism, and unmodeled effects of the proximal section shape. A separable TDRM which overcomes difficulties in actuation and sterilization is introduced, in which the body containing the electronics is reusable and the remainder is disposable. An open-loop redundant controller which resolves the redundancy in the kinematics is developed. Simple linear hysteresis compensation and re-tension compensation based on the physical properties of the device are proposed. The controller and compensation methods are evaluated on a testbed for a straight proximal section, a curved proximal section at various static angles, and a proximal section which dynamically changes angles; and overall, distal tip error was reduced.

Identifiers

PMID38328596
PMCPMC10845131

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.