Evidence map›Paper›PMID 38326603›Full record

ArticleMikrochimica acta2024

Antibody-functionalized gold nanoclusters/gold nanoparticle platform for the fluorescence turn-on detection of cardiac troponin I.

S Madanan Anju, K Abraham Merin, Susan Varghese, Ali Ibrahim Shkhair, Greeshma Rajeevan, Geneva Indongo, Sony George

Abstract read
PubMed Publisher
In one paragraph

Article in Mikrochimica acta, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
2.7field-weighted citation impact, top 6% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 23 citations in OpenAlex.

  1. Review
  2. Review
  3. Review
  4. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 1 institution in 1 country.

S Madanan AnjuDepartment of Chemistry, School of Physical and Mathematical Science, University of Kerala, Thiruvananthapuram, Kerala, 695581, India.
K Abraham MerinDepartment of Chemistry, School of Physical and Mathematical Science, University of Kerala, Thiruvananthapuram, Kerala, 695581, India.
Susan VargheseDepartment of Chemistry, School of Physical and Mathematical Science, University of Kerala, Thiruvananthapuram, Kerala, 695581, India.
Ali Ibrahim ShkhairDepartment of Chemistry, School of Physical and Mathematical Science, University of Kerala, Thiruvananthapuram, Kerala, 695581, India.
Greeshma RajeevanDepartment of Chemistry, School of Physical and Mathematical Science, University of Kerala, Thiruvananthapuram, Kerala, 695581, India.
Geneva IndongoDepartment of Chemistry, School of Physical and Mathematical Science, University of Kerala, Thiruvananthapuram, Kerala, 695581, India.
Sony GeorgeDepartment of Chemistry, School of Physical and Mathematical Science, University of Kerala, Thiruvananthapuram, Kerala, 695581, India. emailtosony@gmail.com.
University of Kerala · IN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

A selective fluorescence turn-on immunosensor for the specific detection of cardiac troponin I (cTnI), the potent biomarker for myocardial infarction diagnosis, was developed with a nano couple comprised of protein-stabilized gold nanocluster and gold nanoparticle. The red fluorescence of cTnI-specific antibody tagged bovine serum albumin stabilized gold nanoclusters was quenched with gold nanoparticles (AuNP) via the intensive interaction between amine and hydroxyl functionalities of BSA and AuNP. Through this, the adsorption of gold nanoclusters at the surface of AuNP, resulting in a core-satellite assembly, was assumed to quench the fluorescence emission. While in the presence of cTnI antigen, this gets disturbed due to the formation of immunocomplex between cTnI antigen and antibody, which restricts the close interaction between gold clusters and nanoparticles, thereby restoring quenched fluorescence. The enhancement in fluorescence signal is directly related to the concentration of cTnI, and this facilitates the selective detection of cTnI in the linear concentration range 0.7 to 10 ng/mL without any interference from other potentially interfering co-existing biomolecules. An appreciable limit of detection of 0.51 ng/mL and a limit of quantification of 0.917 ng/mL for cTnI is comparable to that of the previous report.

Indexed as

Biosensing TechniquesMetal NanoparticlesAntibodiesGoldImmunoassayTroponin IAntibodiesGoldTroponin IBiomarkerCardiac troponinImmuno sensorMyocardial infractionPoint of care device

Identifiers

PMID38326603
OpenAlexW4391648378

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.