Evaluation of functional and electrical features of automatic external defibrillators in extreme altitude and temperature environments.
Article in Resuscitation plus, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed.
- Agentic AI can help hospitals prepare for unprecedented weather.NPJ digital medicine · 2026Article
- Effect of Thermal and Vibration Changes on Automated External Defibrillator Circuit Boards: Finite Element Analysis Study.JMIRx med · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Aims: Human exposure to high-altitude and/or low-temperature areas is increasing and cardiac arrest in these circumstances represents an increasing proportion of all treated cardiac arrests. However, little is known about the performance of automated external defibrillators (AED) in these circumstances. The objective of this study is to assess the functional and electrical features of 6 commercially available AEDs in extreme environments. Methods: Accuracy of shockable rhythm detection, the time required for self-test, rhythm analysis, and capacitor charging, together with total energy, peak voltage, peak current, and phasic duration of defibrillation waveform measured after placing the AEDs in simulated high-altitude, simulated low-temperature, and natural composite high-altitude and low-temperature environment for 30 min, were compared to those measured in the standard environment. Results: All of the shockable rhythms were correctly detected and all of the defibrillation shocks were successfully delivered by the AEDs. However, the time required for self-test, rhythm detection, and capacitor charging was shortened by 1.2% (3 AEDs, maximum 12.4%) in the simulated high-altitude environment, was prolonged by 3.6% (4 AEDs, maximum 40.8%) in the simulated low-temperature environment, and was prolonged by 4.1% (5 AEDs, maximum 52.1%) in the natural environment. Additionally, the total delivered energy was decreased by 2.5% (2 AEDs, maximum 6.8%) in the natural environment. Conclusion: All of the investigated AEDs functioned properly in simulated and natural environments, but a large variation in the functional and electrical feature change was observed. When performing cardiopulmonary resuscitation in extreme environments, the impact of environmental factors may need consideration.