ArticleFrontiers in cardiovascular medicine2024
Implantable cardiac monitors: artificial intelligence and signal processing reduce remote ECG review workload and preserve arrhythmia detection sensitivity.
Article in Frontiers in cardiovascular medicine, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
8 citing papers in PubMed.
- From wrist to heart: clinical validation and real-world translation of wearable and portable AI-enhanced electrocardiography.European heart journal. Digital health · 2026Review
- A Multi-Center Trained Residual Neural Network for Robust Classification of Atrial High-Rate Episodes in Remotely Monitored Pacemakers and Defibrillators.Sensors (Basel, Switzerland) · 2026Article
- AI-Enabled Sensor Technologies for Remote Arrhythmic Monitoring in High-Risk Cardiomyopathy Genotypes.Sensors (Basel, Switzerland) · 2026Review
- Atrial fibrillation detection performance of an insertable cardiac monitor: Results from an Assert-IQ post-market clinical study and a novel artificial intelligence algorithm.Heart rhythm O2 · 2026Article
- Real-world use of insertable cardiac monitor remote programming: A multicenter European experience.Heart rhythm O2 · 2025Article
- From Clinic to Cloud: Efficacy of AI-Assisted Remote Monitoring of Patients With Implantable Cardiac Devices.Pacing and clinical electrophysiology : PACE · 2025Review
- The hope and the hype of artificial intelligence for syncope management.European heart journal. Digital health · 2025Article
- Revolutionizing electrocardiography: the role of artificial intelligence in modern cardiac diagnostics.Annals of medicine and surgery (2012) · 2025Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
15 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Introduction: Implantable cardiac monitors (ICMs) provide long-term arrhythmia monitoring, but high rates of false detections increase the review burden. The new "SmartECG" algorithm filters false detections. Using large real-world data sets, we aimed to quantify the reduction in workload and any loss in sensitivity from this new algorithm. Methods: Patients with a BioMonitor IIIm and any device indication were included from three clinical projects. All subcutaneous ECGs (sECGs) transmitted via remote monitoring were classified by the algorithm as "true" or "false." We quantified the relative reduction in workload assuming "false" sECGs were ignored. The remote monitoring workload from five hospitals with established remote monitoring routines was evaluated. Loss in sensitivity was estimated by testing a sample of 2000 sECGs against a clinical board of three physicians. Results: Of our population of 368 patients, 42% had an indication for syncope or pre-syncope and 31% for cryptogenic stroke. Within 418.5 patient-years of follow-up, 143,096 remote monitoring transmissions contained 61,517 sECGs. SmartECG filtered 42.8% of all sECGs as "false," reducing the number per patient-year from 147 to 84. In five hospitals, nine trained reviewers inspected on average 105 sECGs per working hour. This results in an annual working time per patient of 83 min without SmartECG, and 48 min with SmartECG. The loss of sensitivity is estimated as 2.6%. In the majority of cases where true arrhythmias were rejected, SmartECG classified the same type of arrhythmia as "true" before or within 3 days of the falsely rejected sECG. Conclusion: SmartECG increases efficiency in long-term arrhythmia monitoring using ICMs. The reduction of workload by SmartECG is meaningful and the risk of missing a relevant arrhythmia due to incorrect filtering by the algorithm is limited.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials