Evidence map›Paper›PMID 38322767›Full record

ArticleFrontiers in cardiovascular medicine2024

Implantable cardiac monitors: artificial intelligence and signal processing reduce remote ECG review workload and preserve arrhythmia detection sensitivity.

Giovanni Bisignani, Jim W Cheung, Roberto Rordorf, Valentina Kutyifa, Daniel Hofer, Dana Berti, Luigi Di Biase, Eimo Martens, Vincenzo Russo, Paolo Vitillo and 5 more

Abstract read
In one paragraph

Article in Frontiers in cardiovascular medicine, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed.

  1. Review
  2. Article
  3. Review
  4. Article
  5. Article
  6. Review
  7. Article
  8. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

15 authors.

Giovanni BisignaniDepartment of Cardiology, Ospedale Civile Ferrari, Castrovillari, Italy.
Jim W CheungDivision of Cardiology, Weill Cornell Medicine, New York, NY, United States.
Roberto RordorfDepartment of Cardiology, IRCCS Policlinico San Matteo, Pavia, Italy.
Valentina KutyifaClinical Cardiovascular Research Center, University of Rochester, Rochester, NY, United States.
Daniel HoferDepartment of Cardiology, University Hospital Zurich, Zurich, Switzerland.
Dana BertiDepartment of Cardiology, Jessa Ziekenhuis, Hasselt, Belgium.
Luigi Di BiaseArrhythmia Services, Albert Einstein College of Medicine at Montefiore Health System, New York, NY, United States.
Eimo MartensDepartment of Cardiology, Klinikum rechts der Isar, Technical University Munich, Munich, Germany.
Vincenzo RussoDepartment of Cardiology, University Vanvitelli, Monaldi Hospital, Napoli, Italy.
Paolo VitilloDepartment of Cardiology, Azienda Ospedaliera di Rilievo Nazionale e di Alta Specialità San Giuseppe Moscati, Avellino, Italy.
Marlies ZoutendijkDepartment of Cardiology, Admiraal de Ruyter Ziekenhuis, Goes, Netherlands.
Thomas DenekeDepartment of Cardiology, Rhön Clinic Campus Bad Neustadt, Bad Neustadt a. d. Saale, Germany.
Irina KöhlerBiotronik SE & CO. KG, Berlin, Germany.
Jürgen SchraderBiotronik SE & CO. KG, Berlin, Germany.
Gaurav UpadhyayCenter for Arrhythmia Care, University of Chicago Medicine, Chicago, IL, United States.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Introduction: Implantable cardiac monitors (ICMs) provide long-term arrhythmia monitoring, but high rates of false detections increase the review burden. The new "SmartECG" algorithm filters false detections. Using large real-world data sets, we aimed to quantify the reduction in workload and any loss in sensitivity from this new algorithm. Methods: Patients with a BioMonitor IIIm and any device indication were included from three clinical projects. All subcutaneous ECGs (sECGs) transmitted via remote monitoring were classified by the algorithm as "true" or "false." We quantified the relative reduction in workload assuming "false" sECGs were ignored. The remote monitoring workload from five hospitals with established remote monitoring routines was evaluated. Loss in sensitivity was estimated by testing a sample of 2000 sECGs against a clinical board of three physicians. Results: Of our population of 368 patients, 42% had an indication for syncope or pre-syncope and 31% for cryptogenic stroke. Within 418.5 patient-years of follow-up, 143,096 remote monitoring transmissions contained 61,517 sECGs. SmartECG filtered 42.8% of all sECGs as "false," reducing the number per patient-year from 147 to 84. In five hospitals, nine trained reviewers inspected on average 105 sECGs per working hour. This results in an annual working time per patient of 83 min without SmartECG, and 48 min with SmartECG. The loss of sensitivity is estimated as 2.6%. In the majority of cases where true arrhythmias were rejected, SmartECG classified the same type of arrhythmia as "true" before or within 3 days of the falsely rejected sECG. Conclusion: SmartECG increases efficiency in long-term arrhythmia monitoring using ICMs. The reduction of workload by SmartECG is meaningful and the risk of missing a relevant arrhythmia due to incorrect filtering by the algorithm is limited.

Indexed as

artificial intelligencecardiac arrhythmiaemployee workloadimplantable cardiac monitorremote monitoring

Identifiers

PMID38322767
PMCPMC10844377

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.