Evidence map›Paper›PMID 38321514›Full record

ArticleBMC nursing2024

Spanish transcultural adaptation of the 4AT score for the evaluation of delirium in the emergency department: a prospective diagnostic test accuracy study.

Marta Morales-Puerto, María Ruiz-Díaz, Silvia García-Mayor, Álvaro León-Campos, José Miguel Morales-Asencio, José Carlos Canca-Sánchez, Sonia Gavira-Guerra, Cecilia Toledo-Fernandez, Marta Aranda-Gallardo

Abstract read
In one paragraph

Article in BMC nursing, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Review
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Marta Morales-PuertoHospital Costa del Sol. Servicio Andaluz de Salud, Autovía A7, Km. 187. Marbella, Malaga, 29603, Spain.
María Ruiz-DíazHospital Costa del Sol. Servicio Andaluz de Salud, Autovía A7, Km. 187. Marbella, Malaga, 29603, Spain.
Silvia García-MayorFaculty of Health Sciences, Department of Nursing, Universidad de Málaga, C/ Arquitecto Francisco Peñalosa 3, Malaga, 29017, Spain.
Álvaro León-CamposFaculty of Health Sciences, Department of Nursing, Universidad de Málaga, C/ Arquitecto Francisco Peñalosa 3, Malaga, 29017, Spain. alvaroleon@uma.es.
José Miguel Morales-AsencioFaculty of Health Sciences, Department of Nursing, Universidad de Málaga, C/ Arquitecto Francisco Peñalosa 3, Malaga, 29017, Spain.
José Carlos Canca-SánchezHospital Costa del Sol. Servicio Andaluz de Salud, Autovía A7, Km. 187. Marbella, Malaga, 29603, Spain.
Sonia Gavira-GuerraHospital Costa del Sol. Servicio Andaluz de Salud, Autovía A7, Km. 187. Marbella, Malaga, 29603, Spain.
Cecilia Toledo-FernandezHospital Costa del Sol. Servicio Andaluz de Salud, Autovía A7, Km. 187. Marbella, Malaga, 29603, Spain.
Marta Aranda-GallardoHospital Costa del Sol. Servicio Andaluz de Salud, Autovía A7, Km. 187. Marbella, Malaga, 29603, Spain.

Funding

Andalusian Regional Ministry of Health PI-0107-2020
6 · The paper itself

Abstract

backgroundDelirium is one of the most common adverse events in older people during hospitalization, especially in the emergency department. Reliable, easy-to-use instruments are necessary to properly manage delirium in this setting. This study aims to evaluate the diagnostic validity of the Spanish version of the 4 'A's Test (4AT) in the ED.

methodsA diagnostic accuracy study was conducted in patients over 65 years old admitted to the Emergency Department who did not have a formal diagnosis of dementia or a severe mental health disorder. Face and content validity were evaluated by an expert panel. Emergency nurses performed the evaluation with 4AT, whilst blinded and trained researchers assessed patients with the Revised Delirium Rating Scale as the gold standard. The content validity index, sensitivity, specificity, positive and negative predictive values, likelihood ratios, Youden's Index and ROC curves were calculated to evaluate the diagnostic accuracy of the instrument.

resultsOf 393 eligible patients, 380 were finally analyzed. Content validity yielded a median content validity index of 4 (interquartile range: 0). The Spanish 4AT sensitivity (95.83%; 95% ECI: 78.9-99.9%), specificity (92.98%; 95% CI: 89.8-95.4%), positive predictive value (47.92%) and negative predictive value (99.7%) were satisfactory. Youden's index was 0.89. Positive likelihood ratio was 13.65, and negative likelihood ratio 0.045. The area under the curve was 0.97.

conclusionsThe Spanish version of the 4AT for use in the Emergency Departments is easy-to-use and applicable. The validation results indicate that it is a valid instrument with sufficient predictive validity to identify patients at risk of delirium in the Emergency Departments. Moreover, it is a tool that facilitates the management of an adverse event that is associated with increased mortality and morbidity.

Indexed as

4ATAdverse eventsDeliriumMultimorbidityNursingScreening toolValidation study

Identifiers

PMID38321514
PMCPMC10845719

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.