ArticleNature communications2024
Shape-recovery of implanted shape-memory devices remotely triggered via image-guided ultrasound heating.
Article in Nature communications, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
8 citing papers in PubMed.
- Body-responsive shape-memory polymers for biomedical applications.Bioactive materials · 2026Review
- Biofilm-Antagonist Ginger-Based 3D-Printable Photoresins for Complex Implant Designs Exhibiting Advanced Multifunctional Biomedical Applications.Advanced materials (Deerfield Beach, Fla.) · 2026Article
- Advanced Design Concepts for Shape-Memory Polymers in Biomedical Applications and Soft Robotics.Polymers · 2026Review
- Rational Design and Functionalization of Melt Electrowritten 4D Scaffolds for Biomedical Applications.Nano-micro letters · 2026Review
- A Hydro-Expansive and Degradable Biomaterial Enabling Shape Recovery of Film-Based Devices in Biofluids.Advanced materials (Deerfield Beach, Fla.) · 2025Article
- Wearable Ultrasound Devices for Therapeutic Applications.Nano-micro letters · 2025Review
- A Roadmap to Holographic Focused Ultrasound Approaches for Generating Gradient Thermal Patterns.International journal for numerical methods in biomedical engineering · 2025Article
- Mimosa-Inspired Body Temperature-Responsive Shape Memory Polymer Networks: High Energy Densities and Multi-Recyclability.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
19 authors.
Funding
Abstract
Shape-memory materials hold great potential to impart medical devices with functionalities useful during implantation, locomotion, drug delivery, and removal. However, their clinical translation is limited by a lack of non-invasive and precise methods to trigger and control the shape recovery, especially for devices implanted in deep tissues. In this study, the application of image-guided high-intensity focused ultrasound (HIFU) heating is tested. Magnetic resonance-guided HIFU triggered shape-recovery of a device made of polyurethane urea while monitoring its temperature by magnetic resonance thermometry. Deformation of the polyurethane urea in a live canine bladder (5 cm deep) is achieved with 8 seconds of ultrasound-guided HIFU with millimeter resolution energy focus. Tissue sections show no hyperthermic tissue injury. A conceptual application in ureteral stent shape-recovery reduces removal resistance. In conclusion, image-guided HIFU demonstrates deep energy penetration, safety and speed.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.