ArticlePractical laboratory medicine2024

Comparison of plasma aldosterone measured by chemiluminescence immunoassay and liquid chromatography-tandem mass spectrometry in screening test for primary aldosteronism.

Wenzhan Chen, Fenghua Lai, Xiaoyu Huang, Shuang Yu, Nan Chen, Changliu Xu, Chenxue Wang, Shuhui Liang, Yanbing Li, Haipeng Xiao and 1 more

Abstract read
In one paragraph

Article in Practical laboratory medicine, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Wenzhan ChenDepartment of Endocrinology, The First Affiliated Hospital, Sun Yat-Sen University, Guangzhou, China.
Fenghua LaiDepartment of Endocrinology, The First Affiliated Hospital, Sun Yat-Sen University, Guangzhou, China.
Xiaoyu HuangDepartment of Endocrinology, The First Affiliated Hospital, Sun Yat-Sen University, Guangzhou, China.
Shuang YuDepartment of Endocrinology, The First Affiliated Hospital, Sun Yat-Sen University, Guangzhou, China.
Nan ChenDepartment of Endocrinology, The First Affiliated Hospital, Sun Yat-Sen University, Guangzhou, China.
Changliu XuDepartment of Endocrinology, The First Affiliated Hospital, Sun Yat-Sen University, Guangzhou, China.
Chenxue WangDepartment of Endocrinology, The First Affiliated Hospital, Sun Yat-Sen University, Guangzhou, China.
Shuhui LiangDepartment of Endocrinology, The First Affiliated Hospital, Sun Yat-Sen University, Guangzhou, China.
Yanbing LiDepartment of Endocrinology, The First Affiliated Hospital, Sun Yat-Sen University, Guangzhou, China.
Haipeng XiaoDepartment of Endocrinology, The First Affiliated Hospital, Sun Yat-Sen University, Guangzhou, China.
Xiaopei CaoDepartment of Endocrinology, The First Affiliated Hospital, Sun Yat-Sen University, Guangzhou, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Whether chemiluminescence immunoassay (CLIA) and liquid chromatography-tandem mass spectrometry (LC-MS/MS) for plasma aldosterone concentration (PAC) measurement can be used interchangeably in primary aldosteronism (PA) screening is still controversial. The purpose of this study was to compare CLIA to LC-MS/MS for PAC measurement in PA screening. Methods: All participants underwent aldosterone-to-renin ratio (ARR) testing. PA was diagnosed by captopril challenge test or saline infusion test. PAC in screening test was measured with CLIA and LC-MS/MS. Plasma direct renin concentration in screening and confirmatory test was measured with CLIA. The concordance between CLIA and LC-MS/MS for PAC measurement in PA screening was analyzed. Results: Twenty-one healthy volunteers, 61 patients with essential hypertension (EH) and 43 PA patients were enrolled. Median PAC by CLIA was 84.7 % higher than that by LC-MS/MS in screening test ( Conclusion: CLIA and LC-MS/MS for PAC measurement exhibited high and comparable efficacy in PA screening. CLIA is a reliable and feasible alternative in PA screening test.

Indexed as

Chemiluminescence immunoassayLiquid chromatography with tandem mass spectrometryPrimary aldosteronismScreening test