Evidence map›Paper›PMID 38318026›Full record

ArticleHeliyon2024

Optimizing laser cladding powder injection parameters to shape bioactive glass nano-coated zirconium oxide for biomedical application.

Sathish T, Jayant Giri, R Saravanan

RetractedAbstract readRetracted Publication
In one paragraph

Article in Heliyon, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It has been retracted, and should not be counted. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

3 authors.

Sathish TDepartment of Mechanical Engineering, Saveetha School of Engineering, Saveetha Institute of Medical and Technical Sciences (SIMATS), Saveetha University, Chennai, Tamil Nadu, India.
Jayant GiriDepartment of Mechanical Engineering, Yeshwantrao Chavan College of Engineering, Nagpur, Maharashtra, India.
R SaravananDepartment of Mechanical Engineering, Saveetha School of Engineering, Saveetha Institute of Medical and Technical Sciences (SIMATS), Saveetha University, Chennai, Tamil Nadu, India.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Human body is highly sensitive and repairing often incurs pain and expenses. Strength of the materials degraded by poor joint (either weld or link). New material technology is proposed many biomaterials for repairing bone and tissue and also many bio-implantation applications. Especially bioactive material like bioactive glass is used for biomedical applications for replacement and repairing organs in human body. This research work focuses on suggesting material of S53P4 bioactive glass Nano-coated Zirconium dioxide for manufacturing artificial knee implant for fixing in human body. The substrate of Zirconium dioxide is Nano-coated with S53P4 bioactive glass by means of laser cladding process. The laser cladding process parameters were optimized by Taguchi method to enhance mechanical properties like compressive strength, wear resistance and microhardness of Zirconium dioxide implant material. The key parameters like Laser Power (1 kW, 2 kW, 3 kW and 4 kW), beam diameter (2 mm, 3 mm, 4 mm and 5 mm), powder feed rate (10 g/min, 15 g/min, 20 g/min and 25 g/min) and scanning speed (3 mm/s, 4 mm/s, 5 mm/s and 6 mm/s) were considered. The optimal parameters result the higher compressive strength and microhardness are obtained as 373 MPa and 898.37 HV0.2 and minimum wear volume is attained as 0.148 mm

Indexed as

BiomaterialsBiomedicalCompressive strengthLaser powerMicrohardnessTaguchi methodWear

Identifiers

PMID38318026
PMCPMC10839605

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.