A Systematic Prospective Comparison of Fluid Volume Evaluation across OCT Devices Used in Clinical Practice.
Article in Ophthalmology science. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
4 citing papers in PubMed.
- Rapid Effects on Anatomical and Functional Outcomes following Upload with Faricimab in Treatment-Naïve nAMD: German Single-Center Study 45DRY.Ophthalmology and therapy · 2026Article
- Scan Density Matters: Reproducibility of AI-Derived OCT Biomarkers in Diabetic Macular Edema.Translational vision science & technology · 2026Article
- Comparison of choroidal hypertransmission and retinal pigment epithelium loss for quantification of geographic atrophy across commonly used SD-OCT devices.Scientific reports · 2026Article
- The impact of swithching faricimab in the treatment of neovascular age-related macular degeneration: a real-world analysis.Graefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
11 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Objective: Treatment decisions in neovascular age-related macular degeneration (nAMD) are mainly based on subjective evaluation of OCT. The purpose of this cross-sectional study was to provide a comparison of qualitative and quantitative differences between OCT devices in a systematic manner. Design: Prospective, cross-sectional study. Subjects: One hundred sixty OCT volumes, 40 eyes of 40 patients with nAMD. Methods: Patients from clinical practice were imaged with 4 different OCT devices during one visit: (1) Spectralis Heidelberg; (2) Cirrus; (3) Topcon Maestro2; and (4) Topcon Triton. Intraretinal fluid (IRF), subretinal fluid (SRF), and pigment epithelial detachment (PED) were manually annotated in all cubes by trained human experts to establish fluid measurements based on expert-reader annotations. Intraretinal fluid, SRF, and PED volume were quantified in nanoliters (nL). Bland-Altman plots were created to analyze the agreement of measurements in the central 1 and 6 mm. The Friedman test was performed to test for significant differences in the central 1, 3, and 6 mm. Main Outcome Measures: Intraretinal fluid, SRF, and PED volume. Results: In the central 6 mm, there was a trend toward higher IRF and PED volumes in Spectralis images compared with the other devices and no differences in SRF volume. In the central 1 mm, the standard deviation of the differences ranged from ± 3 nL to ± 6 nL for IRF, from ± 3 nL to ± 4 nL for SRF, and from ± 7 nL to ± 10 nL for PED in all pairwise comparisons. Manually annotated IRF and SRF volumes showed no significant differences in the central 1 mm. Conclusions: Fluid volume quantification achieved excellent reliability in all 3 retinal compartments on images obtained from 4 OCT devices, particularly for clinically relevant IRF and SRF values. Although fluid volume quantification is reliable in all 4 OCT devices, switching OCT devices might lead to deviating fluid volume measurements with higher agreement in the central 1 mm compared with the central 6 mm, with highest agreement for SRF volume in the central 1 mm. Understanding device-dependent differences is essential for expanding the interpretation and implementation of pixel-wise fluid volume measurements in clinical practice and in clinical trials. Financial Disclosures: Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.