Evidence map›Paper›PMID 38316912›Full record

ArticleCommunications medicine2024

Realtime monitoring of thrombus formation in vivo using a self-reporting vascular access graft.

Daniel Hoare, David Kingsmore, Michael Holsgrove, Ewan Russell, Mahmut T Kirimi, Jakub Czyzewski, Nosrat Mirzai, Simon Kennedy, Steven L Neale, John R Mercer

Open access · goldAbstract read
In one paragraph

Article in Communications medicine, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
6.7field-weighted citation impact, top 3% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 9 citations in OpenAlex.

  1. Article
  2. Review
  3. Review
  4. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors at 2 institutions in 1 country.

Daniel HoareSchool of Cardiovascular & Metabolic Health, University of Glasgow, Glasgow, UK.
David KingsmoreQueen Elizabeth University Hospital, University of Glasgow, Glasgow, UK.ORCID http://orcid.org/0000-0002-0401-2178
Michael HolsgroveBioelectronics Unit, College of Medical, Veterinary and Life Sciences, University of Glasgow, Glasgow, UK.
Ewan RussellBioelectronics Unit, College of Medical, Veterinary and Life Sciences, University of Glasgow, Glasgow, UK.
Mahmut T KirimiQueen Elizabeth University Hospital, University of Glasgow, Glasgow, UK.
Jakub CzyzewskiBioelectronics Unit, College of Medical, Veterinary and Life Sciences, University of Glasgow, Glasgow, UK.ORCID http://orcid.org/0009-0004-8168-1334
Nosrat MirzaiBioelectronics Unit, College of Medical, Veterinary and Life Sciences, University of Glasgow, Glasgow, UK.
Simon KennedySchool of Cardiovascular & Metabolic Health, University of Glasgow, Glasgow, UK.
Steven L NealeCentre for Medical and Industrial Ultrasonics, James Watt School of Engineering, University of Glasgow, Glasgow, UK.
John R MercerSchool of Cardiovascular & Metabolic Health, University of Glasgow, Glasgow, UK. John.Mercer@glasgow.ac.uk.ORCID http://orcid.org/0000-0002-3204-7511
University of Glasgow · GBQueen Elizabeth University Hospital · GB

Funding

Medical Research Council MC_PC_19039Wellcome Trust
6 · The paper itself

Abstract

backgroundChronic kidney disease (CKD) affects 10% of the global population costing over a hundred billion dollars per annum and leading to increased risk of cardiovascular disease. Many patients with CKD require regular haemodialyses. Synthetic arteriovenous grafts (AVG) are increasingly used to provide rapid vascular connection for dialysis. Initially, they have excellent patency rates but are critically limited by neointimal hyperplasia at the venous anastomosis, which drives subsequent thrombosis, graft failure and death.

methodsHere, we describe a system in which electrical impedance spectroscopy sensors are incorporated circumferentially into the wall of a synthetic arteriovenous graft. This is combined with an implantable radiotelemetry system for data transmission outside the patient. The system was tested using monolayers of endothelial and smooth muscle cells as well as swine blood and clots with explanted human carotid artery plaques. Sensor testing was then performed in vitro and the device was implanted in vivo in female swine.

resultsThe device can wirelessly report the accumulation of biological material, both cells and blood. Differences are also detected when comparing controls with pathological atheroma. In swine differences between blockage formation in a graft were remotely obtained and wireless reported.

conclusionsCombining electrical impedance spectroscopy and an implantable radiotelemetry system enables graft surveillance. This has the potential to be used for early detection of venous stenosis and blood clot formation in real-time in vivo. In principle, the concept could apply to other cardiovascular diseases and vascular implantable devices.

Identifiers

PMID38316912
PMCPMC10844314
OpenAlexW4391538977

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.