Evidence map›Paper›PMID 38316856›Full record

ArticleScientific reports2024

Minimizing artifact-induced false-alarms for seizure detection in wearable EEG devices with gradient-boosted tree classifiers.

Thorir Mar Ingolfsson, Simone Benatti, Xiaying Wang, Adriano Bernini, Pauline Ducouret, Philippe Ryvlin, Sandor Beniczky, Luca Benini, Andrea Cossettini

Open access · goldAbstract read
In one paragraph

Article in Scientific reports, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
13citing papers in PubMed, 1 pooled it
10.6field-weighted citation impact, top 1% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

13 citing papers in PubMed, 1 synthesis or guideline pooled it, 31 citations in OpenAlex.

  1. Pooled it
  2. Article
  3. Article
  4. Article
  5. Article
  6. Review
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 4 institutions in 3 countries.

Thorir Mar IngolfssonETH Zürich, D-ITET, 8092, Zürich, Switzerland. thoriri@iis.ee.ethz.ch.
Simone BenattiUniversity of Bologna, 40126, Bologna, Italy.
Xiaying WangETH Zürich, D-ITET, 8092, Zürich, Switzerland.
Adriano BerniniUniversity Hospital of Lausanne (CHUV), 1011, Lausanne, Switzerland.
Pauline DucouretUniversity Hospital of Lausanne (CHUV), 1011, Lausanne, Switzerland.
Philippe RyvlinUniversity Hospital of Lausanne (CHUV), 1011, Lausanne, Switzerland.
Sandor BeniczkyAarhus University Hospital, 8200, Aarhus, Denmark.
Luca BeniniETH Zürich, D-ITET, 8092, Zürich, Switzerland.
Andrea CossettiniETH Zürich, D-ITET, 8092, Zürich, Switzerland.
ETH Zurich · CHUniversity Hospital of Lausanne · CHFiladelfia · DKUniversity of Bologna · IT

Funding

Schweizerischer Nationalfonds zur Förderung der Wissenschaftlichen Forschung 193813
6 · The paper itself

Abstract

Electroencephalography (EEG) is widely used to monitor epileptic seizures, and standard clinical practice consists of monitoring patients in dedicated epilepsy monitoring units via video surveillance and cumbersome EEG caps. Such a setting is not compatible with long-term tracking under typical living conditions, thereby motivating the development of unobtrusive wearable solutions. However, wearable EEG devices present the challenges of fewer channels, restricted computational capabilities, and lower signal-to-noise ratio. Moreover, artifacts presenting morphological similarities to seizures act as major noise sources and can be misinterpreted as seizures. This paper presents a combined seizure and artifacts detection framework targeting wearable EEG devices based on Gradient Boosted Trees. The seizure detector achieves nearly zero false alarms with average sensitivity values of [Formula: see text] for 182 seizures from the CHB-MIT dataset and [Formula: see text] for 25 seizures from the private dataset with no preliminary artifact detection or removal. The artifact detector achieves a state-of-the-art accuracy of [Formula: see text] (on the TUH-EEG Artifact Corpus dataset). Integrating artifact and seizure detection significantly reduces false alarms-up to [Formula: see text] compared to standalone seizure detection. Optimized for a Parallel Ultra-Low Power platform, these algorithms enable extended monitoring with a battery lifespan reaching 300 h. These findings highlight the benefits of integrating artifact detection in wearable epilepsy monitoring devices to limit the number of false positives.

Indexed as

EpilepsyWearable Electronic DevicesAlgorithmsArtifactsElectroencephalographyHumansSeizures

Identifiers

PMID38316856
PMCPMC10844293
OpenAlexW4391543324

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.