Evidence map›Paper›PMID 38315598›Full record

ArticleIEEE transactions on bio-medical engineering2024

MR-Safe Cartesian Platform for Active Cardiac Shimming: Preliminary Validation.

Yifan Wang, Mirko Hrovat, Aravindan Kolandaivelu, Anthony L Gunderman, Henry R Halperin, Ehud J Schmidt, Yue Chen

Open access · greenAbstract read
In one paragraph

Article in IEEE transactions on bio-medical engineering, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
0.6field-weighted citation impact, top 38% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 1 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 3 institutions in 1 country.

Yifan Wang
Mirko Hrovat
Aravindan Kolandaivelu
Anthony L Gunderman
Henry R Halperin
Ehud J Schmidt
Yue Chen
Georgia Institute of Technology · USJohns Hopkins University · USMirtech (United States) · US

Funding

Atrial fibrillation ablation assessment and guidance using native-contrast T1 weighted MRIR01HL157259 · NHLBI · JOHNS HOPKINS UNIVERSITY · PI KOLANDAIVELU, ARAVINDAN · 2021 to 2025
$3.9M
Improved arrhythmia ablation via MR-guided robotic catheterization and multimodal clinician feedbackR01EB034359 · NIBIB · GEORGIA INSTITUTE OF TECHNOLOGY · PI Yue Chen, Aravindan Kolandaivelu · 2023 to 2026
$2.5M
Shim System for Removing ICD Artifacts from Patient Cardiac MR ImagesR41HL166053 · NHLBI · MIRTECH, INC. · PI CHEN, YUE, HROVAT, MIRKO I. · 2022 to 2022
$310k
NHLBI NIH HHS R01 HL157259NHLBI NIH HHS R41 HL166053NIBIB NIH HHS R01 EB034359
6 · The paper itself

Abstract

objectiveImplanted Cardioverter Defibrillators (ICDs) induce a large (100 parts per million) inhomogeneous magnetic field in the magnetic resonance imaging (MRI) scanner which cannot be corrected by the scanner's built-in shim coils, leading to significant image artifacts that can make portions of the heart unreadable. To compensate for the field inhomogeneity, an active shim coil capable of countering the field deviation in user-defined regions was designed that must be optimally placed at patient-specific locations. We aim to develop and evaluate an MR-safe robotic solution for automated shim coil positioning.

methodsWe designed and fabricated an MR-safe Cartesian platform that holds the shim coil inside the scanner. The platform consists of three lead screw stages actuated by pneumatic motors, achieving decoupled translations of 140 mm in each direction. The platform is made of plastics and fiberglass with the control electronics placed outside the scanner room, ensuring MR safety. Mechanical modeling was derived to provide design specifications.

resultsExperiments show that the platform achieves less than 2 mm average motion error and 0.5 mm repeatability in all directions, and reduces the adjustment time from 5 min to a few seconds. Phantom and animal trials were conducted, showing that the proposed system is able to position a heavy shim coil ( kg) for improved ICD artifact suppression.

conclusionThis robotic platform provides an effective method for reliable shim coil positioning inside the scanner. SIGNIFICANCE: This work contributes to improving cardiac MRI quality that could facilitate accurate diagnosis and treatment planning for patients with implanted ICDs.

Indexed as

Equipment DesignMagnetic Resonance ImagingPhantoms, ImagingArtifactsDefibrillators, ImplantableHeartHumansReproducibility of ResultsRobotics

Identifiers

PMID38315598
PMCPMC11246563
OpenAlexW4391547491

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.