Construction and validation of an infant chest phantom for paediatric computed tomography.

Seonaid Rodgers, Janette Atkinson, David Cryer, Cameron Storm, Rikki Nezich, Martin A Ebert, Pejman Rowshanfarzad

Abstract readValidation Study
In one paragraph

Article in Physical and engineering sciences in medicine, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Seonaid RodgersDepartment of Medical Technology and Physics, Sir Charles Gairdner Hospital, Hospital Avenue, Nedlands, WA, 6009, Australia. Seonaid.rodgers@health.wa.gov.au.ORCID http://orcid.org/0000-0002-5661-8462
Janette AtkinsonDepartment of Medical Technology and Physics, Sir Charles Gairdner Hospital, Hospital Avenue, Nedlands, WA, 6009, Australia.ORCID http://orcid.org/0000-0003-0188-367X
David CryerDepartment of Medical Technology and Physics, Sir Charles Gairdner Hospital, Hospital Avenue, Nedlands, WA, 6009, Australia.
Cameron StormDepartment of Medical Technology and Physics, Sir Charles Gairdner Hospital, Hospital Avenue, Nedlands, WA, 6009, Australia.ORCID http://orcid.org/0000-0002-3337-3239
Rikki NezichDepartment of Medical Technology and Physics, Sir Charles Gairdner Hospital, Hospital Avenue, Nedlands, WA, 6009, Australia.ORCID http://orcid.org/0000-0002-1473-1379
Martin A EbertSchool of Physics, Mathematics and Computing, University of Western Australia, Crawley, WA, Australia.ORCID http://orcid.org/0000-0002-6875-0719
Pejman RowshanfarzadSchool of Physics, Mathematics and Computing, University of Western Australia, Crawley, WA, Australia.ORCID http://orcid.org/0000-0001-8306-7742

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Paediatric imaging protocols should be carefully optimised to maintain the desired image quality while minimising the delivered patient dose. A paediatric chest phantom was designed, constructed and evaluated to optimise chest CT examinations for infants. The phantom was designed to enable dosimetry and image quality measurements within the anthropomorphic structure. It was constructed using tissue equivalent materials to mimic thoracic structures of infants, aged 0-6 months. The phantom materials were validated across a range of diagnostic tube voltages with resulting CT numbers found equivalent to paediatric tissues observed via a survey of clinical paediatric chest studies. The phantom has been successfully used to measure radiation dose and evaluate various image quality parameters for paediatric specific protocols.

Indexed as

Phantoms, ImagingThoraxTomography, X-Ray ComputedHumansInfantInfant, NewbornRadiation DosageRadiography, ThoracicChestComputed tomographyDiagnosticPaediatricPhantomRadiology

Identifiers

PMID38315414
PMCPMC11166826

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.