Evidence map›Paper›PMID 38314344›Full record

ArticleJournal of clinical and experimental dentistry2024

Shear bond strength of three different metal bracket base designs on human premolars: An

Nataly Corahua-Raymi, Seber Guardia-Huamani, Luis Cervantes-Ganoza, Leonor Castro-Ramírez, Carlos López-Gurreonero, Alberto Cornejo-Pinto, César Cayo-Rojas

Open access · diamondAbstract read
In one paragraph

Article in Journal of clinical and experimental dentistry, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
0.4field-weighted citation impact, top 41% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 2 citations in OpenAlex.

  1. Trial
  2. Article
  3. Article
  4. Review
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 3 institutions in 1 country.

Nataly Corahua-RaymiUniversidad Nacional Federico Villarreal, Faculty of Dentistry, Lima, Peru.
Seber Guardia-HuamaniUniversidad Nacional Federico Villarreal, Faculty of Dentistry, Lima, Peru.
Luis Cervantes-GanozaUniversidad Inca Garcilaso de la Vega, Faculty of Stomatology, Lima, Peru.
Leonor Castro-RamírezUniversidad Privada San Juan Bautista, School of Stomatology, Lima, Peru.
Carlos López-GurreoneroUniversidad Nacional Federico Villarreal, Faculty of Dentistry, Lima, Peru.
Alberto Cornejo-PintoUniversidad Nacional Federico Villarreal, Faculty of Dentistry, Lima, Peru.
César Cayo-RojasUniversidad Nacional Federico Villarreal, Faculty of Dentistry, Lima, Peru.
Federico Villarreal National University · PEUniversidad Inca Garcilaso de la Vega · PEUniversidad Privada San Juan Bautista · PE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Adequate bracket-enamel bonding is critical to prevent detachment during orthodontic treatment and minimize any potential delay in results. The aim was to compare the shear bond strength of three metal bracket base designs: laser-structured base, mesh base, and retention grooves base. Material and Methods: In this experimental in vitro study, 54 human premolars were immersed for one week in 0.1% thymol solution, then placed in distilled water with weekly replacement until the start of the study. The premolars were cemented with brackets of varying base designs: A. Discovery® Smart (laser structured), B. Mini Master® Series (base with mesh), and C. Roth Max (base with retention grooves). All brackets were cemented using TransbondTM XT. A universal testing machine was used to evaluate the shear bond strength at a crosshead speed of 0.75 mm/min. Welch's one-factor ANOVA with robust variance and Tukey's post hoc test were used to compare means, with a significance level of Results: The average shear bond strength values were for the bracket with laser-structured base (14.78 ± 5.79 MPa), the bracket with mesh base (9.64 MPa ± 2.54 MPa) and the bracket with retention groove base (15.38 MPa ± 2.67 MPa). It was found that brackets with mesh bases had significantly lower shear bond strength than brackets with laser-structured bases ( Conclusions: The bracket base design influenced in vitro shear bond strength with significantly higher values observed for Roth Max and Discovery® Smart brackets compared to Mini Master® Series brackets.

Identifiers

PMID38314344
PMCPMC10837803
OpenAlexW4390461212

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.