Evidence map›Paper›PMID 38314023›Full record

ArticleUltrasound (Leeds, England)2024

Depth effect on point shear wave velocity elastography: Evidence in a chronic hepatitis C patient cohort.

Leonardo Rizzo, Luca L'Abbate, Massimo Attanasio, Arturo Montineri, Salvatore Magliocco, Vincenza Calvaruso

Open access · greenAbstract read
In one paragraph

Article in Ultrasound (Leeds, England), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.9field-weighted citation impact, top 24% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 4 citations in OpenAlex.

  1. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 3 institutions in 1 country.

Leonardo RizzoUltrasuoni Srl, Medical Center, Catania, Italy.
Luca L'AbbateDepartment of Biomedical and Dental Sciences and Morphofunctional Imaging, University of Messina, Messina, Italy.
Massimo AttanasioDepartment of Economics, Business and Statistics, University of Palermo, Palermo, Italy.ORCID https://orcid.org/0000-0003-2684-5530
Arturo MontineriDepartment of Infectious Diseases and Tropical Medicine, AOU Policlinico 'G. Rodolico - San Marco', Catania, Italy.
Salvatore MaglioccoDepartment of Infectious Diseases and Tropical Medicine, AOU Policlinico 'G. Rodolico - San Marco', Catania, Italy.
Vincenza CalvarusoGastroenterology and Hepatology Unit, Department of Health Promotion Sciences Maternal and Infantile Care, Internal Medicine and Medical Specialities, PROMISE, University of Palermo, Palermo, Italy.
Policlinico Universitario di Catania · ITUniversity of Palermo · ITUniversity of Messina · IT

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background and Aims: This study investigated the depth-related bias and the influence of scan plane angle on performance of point-shear-wave elastometry in a chronic hepatitis C patient cohort. Materials and Methods: We included 104 patients affected by chronic liver disease related to the hepatitis C virus. Liver surface nodularity was the reference to diagnose cirrhosis. The ultrasound platform was the Siemens S2000, equipped with point-shear-wave elastometry software. Measurements were obtained in left lateral decubitus from the liver surface to the maximum depth of 8 cm in two orthogonal scan planes according to a standard sampling plane. Scatterplot and box plots explored the depth-related bias graphically. The area under the receiver operating characteristic was used to determine the point-shear-wave elastometry diagnostic performance at progressive depths according to liver surface nodularity. Results: Of the 104 patients, 68 were cirrhotics. Depth-related bias equally modified point-shear-wave elastometry in the two orthogonal scan planes. A better point-shear-wave elastometry diagnostic performance was observed between depths of 4 and 5 cm. The frontal scan plane assured better discrimination between cirrhotic patients and non-cirrhotic patients. Conclusion: Depth is crucial for point-shear-wave elastometry performance. Excellent diagnostic performance at a depth between 4 and 5 cm can also be obtained with a smaller number of measurements than previously recommended.

Indexed as

C hepatitisCirrhosisdepthliver fibrosisliver surface nodularity

Identifiers

PMID38314023
PMCPMC10836232
OpenAlexW4386774340

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.