ArticleHeliyon2024
Performance and usefulness evaluation of a software-based scatter correction technique for mammographic images.
Article in Heliyon, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed, 0 citations in OpenAlex.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Although physical grids improve contrast in radiographic images by reducing scattered radiation, various artifacts such as grid shadow, moire, and cutoff result in increased patient doses. To overcome these problems, this study evaluates the applicability and usefulness of a material thickness-based scatter-correction technique for mammography. Specifically, this study aims to compare and evaluate the performance of mammography using the proposed software-based scatter correction framework and a physical grid. The proposed technique enables scatter correction based on pre-calculated parameters of a thickness-based scatter kernel at a water slab phantom and an empirical quantity of scatter components in a mammographic system. In the Monte Carlo simulation and experiment, the proposed framework displayed an intensity profile and full width at half maximum that closely approximated those seen in the physical grid. In addition, by applying the proposed framework to the ACR phantom, it was verified that all structures, including specks, were distinctly distinguished. The results demonstrate that the X-ray scatter-correction method with a software-based framework for mammography is applicable to the field of diagnostic imaging, as this approach yields image quality equivalent to that achieved with physical grids while also enabling a reduction in radiation doses for patients.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.