Evidence map›Paper›PMID 38312281›Full record

ArticleJSES international2024

Bone mineral density around cementless short stems after reverse shoulder arthroplasty: changes over time and its relationship to stem positioning.

Katsumasa Nakazawa, Tomoya Manaka, Yoshihiro Hirakawa, Yoichi Ito, Ryosuke Iio, Naoki Oi, Hiroaki Nakamura

Open access · goldAbstract read
In one paragraph

Article in JSES international, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
1.3field-weighted citation impact, top 20% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 4 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 2 institutions in 1 country.

Katsumasa NakazawaDepartment of Orthopaedic Surgery, Osaka Metropolitan University Graduate School of Medicine, Osaka, Japan.
Tomoya ManakaDepartment of Orthopaedic Surgery, Osaka Metropolitan University Graduate School of Medicine, Osaka, Japan.
Yoshihiro HirakawaIshikiriseiki hospital, Higashiosaka, Japan.
Yoichi ItoOsaka Shoulder Center, Ito Clinic, Osaka, Japan.
Ryosuke IioDepartment of Orthopaedic Surgery, Osaka Metropolitan University Graduate School of Medicine, Osaka, Japan.
Naoki OiOsaka Shoulder Center, Ito Clinic, Osaka, Japan.
Hiroaki NakamuraDepartment of Orthopaedic Surgery, Osaka Metropolitan University Graduate School of Medicine, Osaka, Japan.
Osaka Metropolitan University · JPIshikiriseiki Hospital · JP

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: There are numerous reports of bone adaptation observed on plain radiography studies after the use of cementless short stems in reverse shoulder arthroplasty. However, reports on changes in bone mineral density (BMD) around the stem using dual-energy X-ray absorptiometry (DEXA) are prominently absent. In the present study, we measured BMD around the stem using DEXA and investigated changes over time from postoperative year 1 to year 2. Additionally, the relationship between BMD changes, filling ratio, and stem alignment was examined. Methods: Forty-seven patients with short cementless stems who could be assessed via DEXA at 1-2 years postoperatively were included. After dividing the zones around the stem into 5, the BMD in each zone was measured, in addition to BMD changes and amount of change from postoperative year 1 to year 2. The relationship between filling ratio and stem alignment on postoperative plain radiography was assessed. Results: A significant decrease in BMD in zone 3 was observed between postoperative year 1 and year 2 ( Conclusion: In reverse shoulder arthroplasty cementless short stems, changes that that occurred between postoperative year 1 to year 2 demonstrated a decrease in BMD in zone 3. In addition, a decrease in BMD in zone 1 was observed with a stem alignment of valgus 6° or higher, suggesting that stem alignment within valgus 6° is required to prevent a decrease in BMD.

Indexed as

Bone mineral densityCementless short stemDual-energy X-ray absorptiometryFilling ratioReverse shoulder arthroplastyStem alignment

Identifiers

PMID38312281
PMCPMC10837704
OpenAlexW4386964164

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.