Evidence map›Paper›PMID 38310102›Full record

ArticleScientific reports2024

Rapid prototyping of PMMA-based microfluidic spheroid-on-a-chip models using micromilling and vapour-assisted thermal bonding.

Monieb A M Ahmed, Klaudia M Jurczak, N Scott Lynn, Jean-Paul S H Mulder, Elisabeth M J Verpoorte, Anika Nagelkerke

Abstract read
In one paragraph

Article in Scientific reports, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed.

  1. Exploiting Device Deformability for Fluid and Particle Manipulation.Small (Weinheim an der Bergstrasse, Germany) · 2026
    Review
  2. Review
  3. Article
  4. Article
  5. Article
  6. Article
  7. Review
  8. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Monieb A M AhmedPharmaceutical Analysis, Groningen Research Institute of Pharmacy, University of Groningen, Groningen, The Netherlands.ORCID 0000-0002-0884-7500
Klaudia M JurczakW.J. Kolff Institute for Biomedical Engineering and Materials Science, University Medical Center Groningen, Groningen, The Netherlands.ORCID 0000-0003-2346-2964
N Scott LynnInstitute of Physics, Czech Academy of Sciences, Prague, Czech Republic.ORCID 0000-0002-8649-9214
Jean-Paul S H MulderPharmaceutical Analysis, Groningen Research Institute of Pharmacy, University of Groningen, Groningen, The Netherlands.ORCID 0000-0002-8893-6190
Elisabeth M J VerpoortePharmaceutical Analysis, Groningen Research Institute of Pharmacy, University of Groningen, Groningen, The Netherlands.ORCID 0000-0002-6616-4134
Anika NagelkerkePharmaceutical Analysis, Groningen Research Institute of Pharmacy, University of Groningen, Groningen, The Netherlands. a.p.nagelkerke@rug.nl.ORCID 0000-0002-7541-588X

Funding

Czech Science Foundation 22-20012SEuropean Structural and Investment Funds and Czech Ministry of Education, Youth, and Sports CZ.02.2.69/0.0/0.0/18_053/0016627
6 · The paper itself

Abstract

The application of microfluidic devices as next-generation cell and tissue culture systems has increased impressively in the last decades. With that, a plethora of materials as well as fabrication methods for these devices have emerged. Here, we describe the rapid prototyping of microfluidic devices, using micromilling and vapour-assisted thermal bonding of polymethyl methacrylate (PMMA), to create a spheroid-on-a-chip culture system. Surface roughness of the micromilled structures was assessed using scanning electron microscopy (SEM) and atomic force microscopy (AFM), showing that the fabrication procedure can impact the surface quality of micromilled substrates with milling tracks that can be readily observed in micromilled channels. A roughness of approximately 153 nm was created. Chloroform vapour-assisted bonding was used for simultaneous surface smoothing and bonding. A 30-s treatment with chloroform-vapour was able to reduce the surface roughness and smooth it to approximately 39 nm roughness. Subsequent bonding of multilayer PMMA-based microfluidic chips created a durable assembly, as shown by tensile testing. MDA-MB-231 breast cancer cells were cultured as multicellular tumour spheroids in the device and their characteristics evaluated using immunofluorescence staining. Spheroids could be successfully maintained for at least three weeks. They consisted of a characteristic hypoxic core, along with expression of the quiescence marker, p27

Indexed as

Microfluidic Analytical TechniquesMicrofluidicsChloroformLab-On-A-Chip DevicesPolymethyl MethacrylateChloroformPolymethyl Methacrylate

Identifiers

PMID38310102
PMCPMC10838337

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked