Evidence map›Paper›PMID 38308659›Full record

ArticleJournal of robotic surgery2024

Predictability of implant sizes during cruciate-retaining total knee arthroplasty using an image-free hand-held robotic system.

Krishna Kiran Eachempati, Apurve Parameswaran, Sunil Apsingi, Vinay Kishore Ponnala, Shashwat Agrawal, Neil P Sheth

Abstract read
PubMed Publisher
In one paragraph

Article in Journal of robotic surgery, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
1.7field-weighted citation impact, top 18% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 3 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 2 countries.

Krishna Kiran EachempatiMedicover Hospitals, HITEC City, Hyderabad, India.
Apurve ParameswaranMedicover Hospitals, HITEC City, Hyderabad, India. doctorapurve@gmail.com.
Sunil ApsingiMedicover Hospitals, HITEC City, Hyderabad, India.
Vinay Kishore PonnalaMedicover Hospitals, HITEC City, Hyderabad, India.
Shashwat AgrawalMedicover Hospitals, HITEC City, Hyderabad, India.
Neil P ShethUniversity of Pennsylvania, Philadelphia, USA.
MaxCure Hospitals · INUniversity of Pennsylvania · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The use of appropriately sized implants is critical for achieving optimal gap balance following total knee arthroplasty (TKA). Inappropriately sized implants could result in several complications. Robot-assisted TKA (RA-TKA) using CT-based pre-operative planning predicts implant sizes with high accuracy. There is scant literature describing the accuracy of image-free RA-TKA in predicting implant sizes. The purpose of this study was to assess the accuracy of an image-free robotic system in predicting implant sizes during RA-TKA. Patients who underwent cruciate-retaining RA-TKA for primary osteoarthritis, using an image-free hand-held robotic system were studied. The predicted and implanted sizes of the femoral component, tibial component and polyethylene insert, for 165 patients, were recorded. Agreement between robot-predicted and implanted component sizes was assessed in percentages, while reliability was assessed using Cohen's weighted kappa coefficient. The accuracy of the robotic system was 63% (weighted-kappa = 0.623, P < 0.001), 94% (weighted-kappa = 0.911, P < 0.001) and 99.4% (weighted-kappa = 0.995, P < 0.001), in predicting exact, ± 1 and ± 2 sizes of the femoral component, respectively. For the tibial component, an accuracy of 15.8% (weighted-kappa = 0.207, P < 0.001), 55.8% (weighted-kappa = 0.378, P < 0.001) and 76.4% (weighted-kappa = 0.568, P < 0.001) was noted, for predicting exact, ± 1 and ± 2 sizes respectively. An accuracy of 88.5%, 98.2% and 100%, was noted for predicting exact, ± 1 and ± 2 sizes of the polyethylene insert respectively. Errors in predicting accurate implant sizes could be multi-factorial. Though the accuracy of image-free RA-TKA with respect to alignment and component positioning is established, the surgeon's expertise should be relied upon while deciding appropriate implant sizes.

Indexed as

Arthroplasty, Replacement, KneeKnee ProsthesisRobotic Surgical ProceduresHumansKnee JointPolyethylenesReproducibility of ResultsPolyethylenesComponent sizingImage-free robotImplant size predictabilityImplant sizing accuracyRobot-assisted total knee arthroplasty

Identifiers

PMID38308659
OpenAlexW4391514601

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.