Evidence map›Paper›PMID 38306632›Full record

ArticleEuropean heart journal. Cardiovascular Imaging2024

Assessment of paravalvular regurgitation after transcatheter aortic valve replacement using 2D multi-velocity encoding and 4D flow cardiac magnetic resonance.

Maxim J P Rooijakkers, Saloua El Messaoudi, Niels A Stens, Marleen H van Wely, Jesse Habets, Monique Brink, Laura Rodwell, Daniel Giese, Rob J van der Geest, Niels van Royen and 1 more

Abstract readComparative Study
In one paragraph

Article in European heart journal. Cardiovascular Imaging, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed.

  1. Review
  2. Article
  3. Article
  4. Review
  5. Article
  6. Review
  7. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Maxim J P RooijakkersDepartment of Cardiology, Radboud University Medical Centre, Geert Grooteplein Zuid 10, 6525 GA, Nijmegen, The Netherlands.ORCID 0000-0002-6815-7667
Saloua El MessaoudiDepartment of Cardiology, Radboud University Medical Centre, Geert Grooteplein Zuid 10, 6525 GA, Nijmegen, The Netherlands.
Niels A StensDepartment of Cardiology, Radboud University Medical Centre, Geert Grooteplein Zuid 10, 6525 GA, Nijmegen, The Netherlands.ORCID 0000-0001-7487-151X
Marleen H van WelyDepartment of Cardiology, Radboud University Medical Centre, Geert Grooteplein Zuid 10, 6525 GA, Nijmegen, The Netherlands.
Jesse HabetsDepartment of Radiology and Nuclear Medicine, Radboud University Medical Centre, Nijmegen, The Netherlands.
Monique BrinkDepartment of Radiology and Nuclear Medicine, Radboud University Medical Centre, Nijmegen, The Netherlands.
Laura RodwellDepartment of Health Sciences, Section Biostatistics, Radboud Institute for Health Sciences, Nijmegen, The Netherlands.ORCID 0000-0003-2706-9326
Daniel GieseMagnetic Resonance, Siemens Healthcare GmbH, Erlangen, Germany.ORCID 0000-0002-3925-4441
Rob J van der GeestDepartment of Medical Imaging, Leiden University Medical Centre, Leiden, The Netherlands.ORCID 0000-0002-9084-5597
Niels van RoyenDepartment of Cardiology, Radboud University Medical Centre, Geert Grooteplein Zuid 10, 6525 GA, Nijmegen, The Netherlands.ORCID 0000-0001-6136-8640
Robin NijveldtDepartment of Cardiology, Radboud University Medical Centre, Geert Grooteplein Zuid 10, 6525 GA, Nijmegen, The Netherlands.ORCID 0000-0003-1530-6363

Funding

Abbott 3810455
6 · The paper itself

Abstract

aimsTo compare the novel 2D multi-velocity encoding (venc) and 4D flow acquisitions with the standard 2D flow acquisition for the assessment of paravalvular regurgitation (PVR) after transcatheter aortic valve replacement (TAVR) using cardiac magnetic resonance (CMR)-derived regurgitant fraction (RF). METHODS AND

resultsIn this prospective study, patients underwent CMR 1 month after TAVR for the assessment of PVR, for which 2D multi-venc and 4D flow were used, in addition to standard 2D flow. Scatterplots and Bland-Altman plots were used to assess correlation and visualize agreement between techniques. Reproducibility of measurements was assessed with intraclass correlation coefficients. The study included 21 patients (mean age ± SD 80 ± 5 years, 9 men). The mean RF was 11.7 ± 10.0% when standard 2D flow was used, 10.6 ± 7.0% when 2D multi-venc flow was used, and 9.6 ± 7.3% when 4D flow was used. There was a very strong correlation between the RFs assessed with 2D multi-venc and standard 2D flow (r = 0.88, P < 0.001), and a strong correlation between the RFs assessed with 4D flow and standard 2D flow (r = 0.74, P < 0.001). Bland-Altman plots revealed no substantial bias between the RFs (2D multi-venc: 1.3%; 4D flow: 0.3%). Intra-observer and inter-observer reproducibility for 2D multi-venc flow were 0.98 and 0.97, respectively, and 0.92 and 0.90 for 4D flow, respectively.

conclusionTwo-dimensional multi-venc and 4D flow produce an accurate quantification of PVR after TAVR. The fast acquisition of the 2D multi-venc sequence and the free-breathing acquisition with retrospective plane selection of the 4D flow sequence provide useful advantages in clinical practice, especially in the frail TAVR population.

Indexed as

Aortic Valve InsufficiencyMagnetic Resonance Imaging, CineTranscatheter Aortic Valve ReplacementAgedAged, 80 and overAortic Valve StenosisBlood Flow VelocityCohort StudiesFemaleHumansMalePostoperative ComplicationsProspective StudiesReproducibility of ResultsSeverity of Illness Indexaortic stenosiscardiac magnetic resonanceparavalvular regurgitationtranscatheter aortic valve replacement

Identifiers

PMID38306632
PMCPMC11210991

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked