Resolving signal drift in the wall-mounted camera of the RGSC system.

Jeonghoon Park, Justin D Gagneur, Suzanne J Chungbin, Yi Rong, Seng Boh Lim, Maria F Chan

Abstract read
In one paragraph

Article in Journal of applied clinical medical physics, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Resolving signal drift in the wall-mounted camera of the RGSC system.Journal of applied clinical medical physics · 2024
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Jeonghoon ParkDepartment of Medical Physics, Memorial Sloan Kettering Cancer Center, Basking Ridge, New Jersey, USA.ORCID https://orcid.org/0000-0002-1142-7419
Justin D GagneurDepartment of Radiation Oncology, Mayo Clinic, Phoenix, Arizona, USA.
Suzanne J ChungbinDepartment of Radiation Oncology, Mayo Clinic, Phoenix, Arizona, USA.
Yi RongDepartment of Radiation Oncology, Mayo Clinic, Phoenix, Arizona, USA.ORCID https://orcid.org/0000-0002-2620-1893
Seng Boh LimDepartment of Medical Physics, Memorial Sloan Kettering Cancer Center, Basking Ridge, New Jersey, USA.ORCID https://orcid.org/0000-0002-4054-8789
Maria F ChanDepartment of Medical Physics, Memorial Sloan Kettering Cancer Center, Basking Ridge, New Jersey, USA.ORCID https://orcid.org/0000-0002-9140-8604

Funding

X-RAY CRYSTALLOGRAPHYP30CA008748 · NCI · SLOAN-KETTERING INSTITUTE FOR CANCER RES · PI Nicholas D Socci · 1985 to 2026
$347.4M
NCI NIH HHS P30 CA008748
6 · The paper itself

Abstract

purposeTo present a modified calibration method to reduce signal drift due to table sagging in Respiratory Gating for Scanner (RGSC) systems with a wall-mounted camera. MATERIALS AND

methodsApproximately 70 kg of solid water phantoms were evenly distributed on the CT couch, mimicking the patient's weight. New calibration measurements were performed at 9 points at the combination of three lateral positions, the CT isocenter and ±10 cm laterally from the isocenter, and three longitudinal locations, the CT isocenter and ±30 cm or ±40 cm from the isocenter. The new calibration was tested in two hospitals.

resultsImplementing the new weighed calibration method at the extended distance yielded improved results during the DIBH scan, reducing the drift to within 1 from 3 mm. The extended calibration positions exhibited similarly reduced drift in both hospitals, reinforcing the method's robustness and its potential applicability across all centers.

conclusionThis proposed solution aims to minimize the systematic error in radiation delivery for patients undergoing motion management with wall-mounted camera RGSC systems, especially in conjunction with a bariatric CT couchtop.

Indexed as

Particle AcceleratorsHumansMotionPhantoms, Imagingcamera calibrationmotion managementRGSC